Integrated Tru-power™ electronic motor and pump protection
- Eliminates need for costly pump protection relays
- Dry pump detection using power (nuisance trip-free); time-based automatic restart and well recovery mode
- Features a wide-range, adjustable, class 5-30 electronic overload
- Provides superior motor protection from the following conditions:
- Over/under power (dry-run)
- Over/under voltage protection
- Voltage phase loss
- Voltage and Current phase unbalance
- Stalled/locked rotor
- Cycle fault
- Ground fault (UL1053 certified)
- Voltage phase reversal
Soft starter features
- Full HP rated bypass contactor
- Across-the-line start for emergency situations (turns the soft-starter into a standard IPS)
- Start modes feature an adjustable current limit, initial voltage, and start time with a torque boost feature
- Stop modes include:
- Coast to stop
- Linear deceleration (reduces water-hammer effect)
- Adjustable stop voltage and stop time
- SCR over-temperature detection
- Shorted SCR detection
Easy to setup and use
- Inside, the display shows an easy to use menu for setting a wealth of parameters. Adjust any protective or control setting in seconds. For example, choose how long to allow for dry well recovery, set run time periods, and On/Off delays. All this with just a few intuitive keystrokes. The IPS-RV ships with factory default settings pre-programmed for optimal submersible pump protection.
Industrial grade construction
- Door mounted heavy-duty HOA switch
- Housed in an outdoor rated, gasketed, NEMA 3R enclosure
- Multi-tap control power transformer with integrated secondary protection accommodates common motor voltages. No fuses required!
- Includes 120 VAC control power for field devices
Advanced programmable pump control
- Automatic fault reset
- Backspin delay - Prevents start-ups into draining systems
- On and Off delay settings
- Well recovery mode (up to 48 hours)
- Minimum run time based on last input
- 12-120 V input for remote start/stop
- Dry contact input for remote start/stop
- Dry contact inputs for float switches
- Analog input for (selectable) 0-10V, 4-20mA, or 10k thermistor, viewable as a Modbus point
Optional circuit breaker disconnect (Service Entrance rated)
- UL 489 circuit breaker provides branch and short circuit protection
- No fuses required – saves time and money
- Lockable handle for safety
Built-in power monitoring, fault logging and communications
- View voltage, current, power factor, and more through an intuitive display
- Built-in fault log, counter and parameter change log: records last 15 fault types with power condition values, stores how many times each fault type has occurred (up to 255 count), and logs changes to parameter settings (e.g. FLA, OV/UV, under power)
- Built-in Modbus RTU communications card
Related
-
200~460v Combination Soft Starter
Part Number 200 V - 460 V
3-Phase SFA
Range** (A)3-PHASE HP (UL) / Max. SFA** Contactor
NEMA Size200 V 230 V 460 V HP SFA HP SFA HP SFA IPS3R-RV-S1-J-G15 6~8 2 8 2 8 5 8 1 IPS3R-RV-S1-J-G20 8~11 3 11 3 11 7.5 11 IPS3R-RV-S1-J-G30 11~17 3 17 5 17 10 17 IPS3R-RV-S1-J-G40 16~22 5 22 7.5 22 15 22 IPS3R-RV-S1P-J-G50 20~28 7.5 28 10 28 20 28 1+ IPS3R-RV-S1P-J-G60 24~34 10 34 10 34 25 34 IPS3R-RV-S2-J-G80 32~45 10 45 15 45 30 45 2 IPS3R-RV-S3-J-G100 40~57 15 57 20 57 40 57 3 IPS3R-RV-S3-J-G125 50~71 20 71 25 71 50 71 IPS3R-RV-S3P-J-G150 60~85 25 85 30 85 60 85 3+ IPS3R-RV-S4-J-G200 80~114 30 114 40 114 75 114 4 IPS3R-RV-S4-J-G250 100~DPV* 40 120 50 130 100 124 IPS3R-RV-S5-J-G250 100~142 40 142 50 142 100 142 5 IPS3R-RV-S5-J-G300 120~170 50 170 50 171 125 171 IPS3R-RV-S5-J-G400 160~220 60 220 75 220 150 220 IPS3R-RV-S5-J-G500 201~285 100 285 100 285 200 285 IPS3R-RV-S5-J-G600 240~320 100 320 100 320 250 320 - Intelligent Pump Soft Starter - 3-Phase, 50/60 Hz, 200~460 VAC
- NEMA Type 3R Enclosed - Combination Soft Starter
- Includes Service Entrance Circuit Breaker Disconnect
200~460v Standard Soft Starter
Part Number 200 V - 460 V
3-Phase SFA
Range** (A)3-PHASE HP (UL) / Max. SFA** Contactor
NEMA Size200 V 230 V 460 V HP SFA HP SFA HP SFA IPS3R-RV-S2-J-50 1~50 15 50 15 50 30 50 2 IPS3R-RV-S3P-J-85 1~85 25 85 30 85 77 85 3+ IPS3R-RV-S4-J-130 50~DPV* 40 120 50 130 100 124 4 IPS3R-RV-S5-J-170 50~170 50 170 60 170 125 170 5 IPS3R-RV-S5-J-220 151~220 60 220 75 220 150 220 IPS3R-RV-S5-J-270 176~270 75 270 100 270 200 270 IPS3R-RV-S5-J-320 201~320 100 320 125 320 250 320 - Intelligent Pump Soft Starter - 3-Phase, 50/60 Hz, 200~460 VAC
- NEMA Type 3R Enclosed - Standard Soft Starter
- Disconnect not Included
600v Combination Soft Starter
Part Number 600 V
3-Phase SFA
Range** (A)3-PHASE HP (UL) / Max. SFA** Contactor
NEMA Size600 V HP SFA IPS3R-RV-S1-6J-G15 6~8 5 8 1 IPS3R-RV-S1-6J-G20 8~11 10 11 IPS3R-RV-S1-6J-G30 11~17 15 17 IPS3R-RV-S1-6J-G40 16~22 20 22 IPS3R-RV-S1P-6J-G50 20~27 25 27 1+ IPS3R-RV-S1P-6J-G60 24~34 30 34 IPS3R-RV-S2-6J-G80 32~45 40 45 2 IPS3R-RV-S3-6J-G100 40~57 50 57 3 IPS3R-RV-S3-6J-G125 50~71 60 71 IPS3R-RV-S3-6J-G150 60~77 75 77 IPS3R-RV-S5-6J-G200 80~114 100 114 5 IPS3R-RV-S5-6J-G250 100~142 125 142 IPS3R-RV-S5-6J-G300 120~170 150 170 IPS3R-RV-S5-6J-G400 160~220 200 220 IPS3R-RV-S5-6J-G500 201~285 250 285 IPS3R-RV-S5-6J-G600 240~289 300 289 - Intelligent Pump Soft Starter - 3-Phase, 50/60 Hz, 600 VAC
- NEMA Type 3R Enclosed - Combination Soft Starter
- Includes Service Entrance Circuit Breaker Disconnect
600v Standard Soft Starter
Part Number 600 V
3-Phase SFA
Range** (A)3-PHASE HP (UL) / Max. SFA** Contactor
NEMA Size600 V HP SFA IPS3R-RV-S2-6J-50 1~50 40 50 2 IPS3R-RV-S3P-6J-77 1~77 75 77 3+ IPS3R-RV-S5-6J-170 50~170 150 170 5 IPS3R-RV-S5-6J-220 151~220 200 220 IPS3R-RV-S5-6J-289 201~289 300 289 - Intelligent Pump Soft Starter - 3-Phase, 50/60 Hz, 600 VAC
- NEMA Type 3R Enclosed - Standard Soft Starter
- Disconnect not Included
Factory Installable Options
Part Number Description IPS-SRG240 Surge Suppressor, 200/230 V IPS-SRG480 Surge Suppressor, 460 V IPS-SRG600 Surge Suppressor, 600 V IPS-RV-SHT Shunt Trip, will trip MCCB in the even of a SCR short IPS-RPL Run Pilot Light, Green IPS-FPL Fault Pilot Light, Red IPS-SPB Start Push-Button Control IPS-STSP Start/Stop Push-Button Control (In Lieu of Hand/Off/Auto Switch) IPS-24 24 VAC Control Circuit (In Lieu of 120 VAC Control Circuit) Dimensions
Intelligent Pump Soft Starter Height Width Depth IPS3R-RV-S2-J-50 32 15 10 IPS3R-RV-S3P-J-XX IPS3R-RV-S4-J-130 36 24 12 IPS3R-RV-S5-J-XXX 42 30 12 IPS3R-RV-S1-J-GXX 32 15 10 IPS3R-RV-S1P-J-GXX IPS3R-RV-S2-J-GXX IPS3R-RV-S3-J-GXXX IPS3R-RV-S3P-J-GXXX IPS3R-RV-S4-J-GXXX 36 24 12 IPS3R-RV-S5-J-G250 42 30 12 IPS3R-RV-S5-J-G300 IPS3R-RV-S5-J-G400 IPS3R-RV-S5-J-G500 48 30 16 IPS3R-RV-S5-J-G600 -
Specification Soft Starter Type IPS-RV - Intelligent Pump Soft Starter Standard or Combination
(Service Rated, Suitable for use as a Service Disconnect)NEMA Type 3R Enclosed User Interface Settings Adjustments Internal Hand-Off-Auto Door mounted 3-position switch Standard Control Operations Inputs Voltage Auto Accepts 12-130VAC/DC.
Applying voltage will send a run command to the starter when in Auto mode.Dry Contact Auto Normally Open dry contact.
When closed, the starter will be commanded to run when in Auto mode.Shutdown Accepts 12-130VAC/DC.
Applying voltage will open the contactor and the starter will not accept a run commandHand/Off/Auto LEDs will flash. Float Switches (2) Programmable Normally Open or Normally Closed dry contacts. RS-485 Modbus RTU slave Analog Selectable: 0-10V, 4-20mA, 10k Thermistor, viewable as a Modbus point Outputs Status Relay Normally Open relay contact, 0.3A @ 125VAC, 1A @ 24VAC Fault Relay Normally Open relay contact, 0.3A @ 125VAC, 1A @ 24VAC Operational Overload Type Electronic, I2t trip curve Power Fail Modes Restart in last mode (Hand/Off/Auto) with no delay (default) Restart in Off mode Restart in Off mode if power failure lasts longer than 2 seconds.
Restart in last mode if power failure is less than 2 seconds.On/Off Time Delay On/Off, Adjustable: 0.1-99 seconds Fault Reset Adjustable: Manual or Automatic (default differs per motor protection feature) Starts 6/hour, 20 seconds max. start time @ 400% FLA, 30 seconds max. start time @ 300% FLA Environmental Ambient Operating Temp -5° to 140° F (-20° to 60° C) Ambient Storage Temp -5° to 185° F (-20° to 85° C) Relative Humidity 5% to 95% non-condensing Motor / Soft Starter Protection Adjustment / Description Default Setting Overload Current Setting Range Differs per model Per SFA Overload Trip Class Adjustable: 5-30 10 Overload Service Factor Adjustable: 0.00-2.00 1.15 Under Power On/Off, Adjustable: 0-99% of measured electrical input On / 60% Over Power On/Off, Adjustable: 101-200% of measured electrical input On / 120% Over / Under Voltage On/Off, Adjustable: +5-25% over/under the nominal voltage setting On / 10% Voltage Phase Unbalance On/Off, Adjustable: 1-20% voltage phase deviation On / 3% Voltage Phase Loss Always On, Adjustable: 1-50% voltage phase deviation 0.1 Voltage Phase Sequence Reversal On/Off, Trips within 0.1 seconds upon voltage phase reversal detection On Ground Fault (UL 1053 Certified) On/Off, Adjustable: 1.0-9.9A On / 1A Cycle Fault On/Off, Adjustable: Trip if cycle rate exceeds 20 starts/minute On Warm Start Provision On/Off, Delays motor restart based on calculated motor temperature On Current Phase Unbalance On/Off, Adjustable: 1-50% current phase unbalance On / 5% Locked Rotor / Stall On/Off, Trips within 0.5 seconds On Shorted SCR Always On: Trips upon detection of a shorted SCR or no motor On Open SCR Always On: Trips if no current is detected during start-up or bypass On SCR Over-Temperature Always On: Trips if the SCR temperature reaches 125oC On Across-the-Line Start On/Off: Allows the user to start the motor across-the-line.
(Turns soft starter into standard IPS)Off -
Manuals