SubMonitor Connect
SubMonitor Connect
3Ø, 50/60 HZ, 200~600 VAC, 1~700 HP
The newly designed SubMonitor Connect features the innovative FE Connect App that provides three-phase motor protection with the enhanced capabilities of real-time performance monitoring to improve troubleshooting. Also enjoy a simple plug-and-play design that provides protection against arc flash, universal power supply, and a NEMA 4X rated display. You can’t always predict overload, dry run, dirty power conditions or other electrical mishaps, but you can be protected from them.

-
Electronic overload motor protection
- Adjustable, class 5-30 electronic overload
- Underload (dry-run protection), for time-based automatic restart with well recovery mode
- Over/under voltage
- Current phase unbalance
- Cycle fault
- Reverse phase
- Easy access to input and output terminals
- 32-character, backlit, NEMA 4x, wash-down rated screen, visible from the front of the panel
- Motor insulation check
Real-time and date-stamped fault logging
- Pre-programmed real time clock with a 10-year battery backup
- Contains separate fault, configuration change, and start logs
- Records up to 150 faults
Application based setup
- Precise protection programming
- Nine-step setup wizard
- Preset protection parameters available for submersible, surface, or custom usages
Related
-
Description Part No. SubMonitor Connect - Standard, 1-135A 5860015010 SubMonitor Connect - Premium, 1-135A* 5860005110 - *Display door mounting kit and surge suppressor included.
Options
Description Part No. SubMonitor Connect Remote Display Assembly 5860015150 Door Mounting Kit 5860015160 External CTs, 120-270A 5860015170 External CTs, 200-400A 5860015180 External CTs, 400-1000A 5860015190 -
Starter Type Standard or combination (service rated for use as a service disconnect) NEMA Type 3R Enclosed Outdoor Rated User Interface Settings Adjustments 32 character, backlit NEMA 4X display. FE Connect Mobile App connected via Bluetooth Hand/Off/Auto Door mounted 3-position switch Standard Control Operations Input RS-485 Modbus RTU slave PT100/1000 On/Off, adjustable: 0-100 C, 212 F Output Fault Relay Normally Open Relay Contact. 1Aa @ 240VAC Operational Overlaod Types Electronic, Simulated I²T trip curve Power Fail Modes Restart in last mode (Hand/Off/Auto) Restart in off mode On/Off Time Delay On/Off, adjustable: 1-60 seconds Backspin Delay On/Off, adjustable: 2 seconds - 60 minutes Fault Reset Adjustable: manual or automatic (default differs per motor protection feature) Starts 6/hour, 20 seconds max start time @ 400% FLA, 30 seconds max start time @ 300% FLA Enviromental Ambient Operating Temp -5 °F to 140 °F (-20 °C to 60 °C) Ambient Storage Temp -5 °F to 185 °F (-20 °C to 85 °C) Relative Humidity 5% to 95% non-condensing Motor/Soft Starter Protection Adjustment/Description Default Setting Overload Current Setting Range Differs per model Per SFA Overload Trip Class Adjustable: 5-30 10 Overload Service Factor Adjustable: 1.00-2.00 1.15 Under Power (Dry Run) On/Off/Alarm, adjustable: 1-99% of nominal On / 65% Over Power On/Off/Alarm, adjustable: 101-200% of nominal On / 125% Under Voltage On/Off/Alarm, adjustable: 80-99% of nominal On / 90 % Over Voltage On/Off/Alarm, adjustable: 101-125% of nominal On / 110 % Voltage Phase Loss Always on On / Trips if below 60VAC Ground Fault (UL 1053 Certified) On/Off/Alarm, adjustable: 1-10 Amps On / 1A Cycle Fault On/Off, Start Limit adjustable: 2-100 On Warm Start Provision On/Off, delays motor restart based on calcualted motor temp On SMARTSTART™ Protection Adjustment/Description Default Setting Current Phase Unbalance On/Off, adjustable: 1-50% On / 5% Locked Rotor/Stall On/Off, trips if current exceeds 300% max amps for 0.5s On Out of Calibration On/Off, trips after 10 seconds if max amps setting is incorrect Off Max Time to Start On/Off, regardless of max amps or I²T trip curve,
always trip at start if starting current is outside of an
acceptabke range and still decreasing after 10 secondsOff -
Brochures
-
Agricultural Solutions Brochure (M5068)
-
Agricultural Solutions Brochure - Spanish (M5068sp)
-
Lake And Pond Management Brochure (M5064)
-
Mining Brochure (M2700)
-
Drives & Controls Panel Sizing Guide (M1754)
-
SubMonitor FE Connect Brochure (M1755)
-
SubMonitor FE Connect Brochure - French (M1755fr)
-
SubMonitor FE Connect Brochure - Spanish (M1755sp)
-
Electronics Manufacturing Brochure (M5075)
-