SubDrive/MonoDrive
SubDrive/MonoDrive
Franklin Electric’s constant pressure controllers use state-of-the-art technology to provide constant water pressure through variable speed control of submersible water well pumps.
Applications
- Residential homes
- Restaurants
- Farms
- Schools
- Car washes
- Landscape irrigation systems
-
Benefits
- Constant water pressure with a wide range of settings (25 to 80 psi)
- Single-phase input power
- FE Connect Smartphone app for advanced settings and monitoring (NEMA 3R only excluding SD2W)
- User-configurable motor frequency range (NEMA 3R only excluding SD2W)
- Easy installation
- Soft-start feature prevents water hammer and increases motor life
- Works with small pressure tanks or existing larger tanks
- Advanced filtering to remove radio frequency interference
- UL and cUL listed
- Built-in diagnostics and protection
- Surge Protection
- Short circuit
- Underload
- Overheated controller
- Undervoltage
- Broken pipe detection (NEMA 3R only excluding SD2W)
- Locked pump
- User-configurable underload off time (NEMA 3R only excluding SD2W)
- Open circuit
MonoDrive Models
MonoDrive and MonoDriveXT are designed to convert a conventional ½ hp to 2 hp pump system to a variable speed constant pressure system by simply replacing the 3-wire control box and pressure switch.
- Single-phase input, 3-wire motor control
- Plug & play
- ½ hp to 2 hp performance
- Easily replaceable fan kit
- Easy to install
- UL and cUL listed
- NEMA 3R and NEMA 4 enclosure options (indoor/outdoor)
SubDrive 3-Phase Models
SubDrive15, SubDrive20, SubDrive30, SubDrive75, SubDrive100, SubDrive150, and SubDrive300 are designed for three-phase motors to provide constant pressure with three-phase performance using single-phase input power.
- Single-phase input, three-phase motor control
- Plug & play
- ¾ hp to 5 hp performance
- Smooth running
- Easy to install
- Easily replaceable fan kit
- High starting torque
- UL and cUL listed
- NEMA 3R and NEMA 4 enclosure options (indoor/outdoor)
SubDrive2W
SubDrive2W is designed to convert a conventional ½ hp, ¾ hp, and 1 hp pump system to a variable speed constant pressure system by simply replacing the pressure switch. Maximum pump output using the SD2W is similar to the performance achieved using a conventional pressure switch. Therefore, the pump selection criteria are the same as if a pressure switch were used. (Refer to the pump manufacturer’s literature for details of the pump selection procedure.)
- Single-phase input, 2-wire motor control
- Plug & play
- ½ hp, ¾ hp, or 1 hp performance
- Easily replaceable air filter kit
- Easy retrofit installation
- Easily replaceable fan kit
- NEMA 3R rated enclosure
- UL and cUL listed
Franklin Drive Family Comparison
QD
PumptecPumptec Pumptec
PlusSubDrive
UtilityMonoDrive
UtilityMonoDrive/
MonoDriveXT
NEMA 4SubDrive
75/100/150/300
NEMA 4MonoDrive/
MonoDriveXT
ConnectSubDrive
15/20/30/50
ConnectSubmersible
Motors1-PHASE
2-WIRE115V 1/3 hp x x 115V 1/2 hp x x 230V 1/3 hp x x x 230V 1/2 hp x x x 230V 3/4 hp x x x 230V 1 hp x x x 230V 1.5 hp x x x 1-PHASE
3-WIRE115V 1/3 hp x x 115V 1/2 hp x x 230V 1/3 hp x x x 230V 1/2 hp x x x x x x x 230V 3/4 hp x x x x x x x 230V 1 hp x x x x x x x 230V 1.5 hp x x x x x x 230V 2 hp x x x x x 230V 3 hp x x 230V 5 hp x 3-PHASE 230V 1 hp x 230V 1.5 hp x x 230V 2 hp x x 230V 3 hp x x 230V 5 hp x x Surface
Pumps1-PHASE
2-WIRE115V 1/3 hp x 115V 1/2 hp x 115V 3/4 hp x 115V 1 hp x 230V 1/3 hp x 230V 1/2 hp x 230V 3/4 hp x 230V 1 hp x 230V 1.5 hp x 230V 2 hp x 3-PHASE 230V 1/3 hp x 230V 1/2 hp x 230V 3/4 hp x 230V 1 hp x 230V 1.5 hp x 230V 2 hp x 230V 3 hp x 230V 5 hp x CONSTANT
PRESSUREx x x x x x Protection/
FeaturesProtection Underload x x x x x x x x x Undervoltage x x x x x x x x x Overvoltage x x x x x x x x x Rapid Cycle x x Soft Start Soft Start Soft Start Soft Start Soft Start Overload /
Locked
Pumpx x x x x x x x x Open Circuit x x x x x x Short Circuit x x x x x x Phase
Imbalancex x Input/
Output/
ControlPressure
Sensor
(Hobbs)x x x x x x Pressure
Transducer
(4-20mA)x x x x Run Relay
OutputAccessory Accessory or
SubDrive300x x Fault Relay
OutputSubDrive300 x x Broken Pipe x x x x Pressure
Sensor
Errorx x x x Auxiliary
Controlx x Wet Floor
Sensorx x Built-In
Duplex
Alternatorx x Mobile App
Advanced
Configurationx x Diagnostic
Fault Historyx x Real-Time
Monitoringx x -
NEMA 3R Constant Pressure Controllers
VFD Enclosure Type Model No. SubDrive15 Connect NEMA 3R, VARIABLE FREQUENCY 5870205103C SubDrive20 Connect NEMA 3R, VARIABLE FREQUENCY 5870205303C SubDrive30 Connect NEMA 3R, VARIABLE FREQUENCY 5870205403C SubDrive50 Connect NEMA 3R, VARIABLE FREQUENCY 5870205503C NEMA 4 Constant Pressure Controllers
VFD Enclosure Type Model No. MonoDrive NEMA 4 VARIABLE FREQUENCY 5870203114 MonoDriveXT NEMA 4 VARIABLE FREQUENCY 5870204114 SubDrive 75 NEMA 4, VARIABLE FREQUENCY 5870203384 SubDrive 100 NEMA 4, VARIABLE FREQUENCY 5870204104 SubDrive 150 NEMA 4, VARIABLE FREQUENCY 5870204154 SubDrive 300 NEMA 4, VARIABLE FREQUENCY 5870206300 -
SubDrive Accessories
Accessories Detail Used With Part No. Air Screen Kit Helps prevent insects from entering and damaging the internal components of the drive SubDrive2W 225835901 Air Screen Kit Helps prevent insects from entering and damaging the internal components of the drive SubDrive15/20/30 Connect and MonoDrive/XT Connect (date code 18A and older) 226550901 Air Screen Kit Helps prevent insects from entering and damaging the internal components of the drive SubDrive50 Connect (date code 18A and older) 226550902 Air Screen Kit Helps prevent insects from entering and damaging the internal components of the drive. Replacement kit for the included standard with SubDrive/MonoDrive connect models built February 2018 and after. SubDrive15/20/30/50 Connect and MonoDrive/MonoDriveXT Connect (date code 18B and newer) 575214902 Analog Pressure Transducer 4-20mA analog pressure transducer (includes 10 ft cable) All Connect and Utility Models - 100 PSI 226905902 All Connect and Utility Models - 150 PSI 226905903 All Connect and Utility Models - 200 PSI 226905904 Analog PressureTransducer Cable Kit Outdoor rated cable to connect analog pressure transducer to the drive All Connect and Utility models - 10 ft 226910901 All Connect and Utility models - 25 ft 226910902 All Connect and Utility models - 50 ft 226910903 All Connect and Utility models - 100 ft 226910904 All Connect and Utility models - 150 ft 226910905 All Connect and Utility models - 200 ft 226910906 Display Board Replacement Kit Replacement board for drives that have a damaged display, DIP switches, or adjustment knobs. All NEMA 3R models (non-Connect) 226540911 Duplex Alternator Allows a water system to alternate between two parallel pumps controlled by separate drives. Must use pressure sensor; not compatible with analog pressure transducer All Models 5850012000 Duplex Alternator Cable Kit Communication cable kit required to use built-in Duplex Alternator function in drives equipped with this feature All Connect models - 10 ft 226895901 All Connect models - 50 ft 226895902 All Connect models - 100 ft 226895903 Enhanced Display Board Replacement Kit Replacement board for drives that have a damaged display, battery holder, or Duplex Alternator communication issue All Connect models 226540912 Enhanced Pressure Input Board Replacement Kit Replacement board for drives that have experienced a surge on the control inputs All Connect models 226540902 Filter (Input) Filter used on the input side of the drive to help eliminate interference All Models 225198901 Filter (Input AMR) Filter used on the input side of the drive to help eliminate interference with automated meter reading systems. All models (excluding SubDrive30/50, SubDrive150, and SubDrive300) 226030901 Filter (Input CE) Filter used on the input side of the drive to attain CE rating SubDrive1100/1500/2200 Connect (CE Models) 226205901 Filter (Input IGF) Filter used in the input side of the drive to help eliminate interference on the ground wire All models 226035901 Filter (Output) Filter used on the output side of the drive to help eliminate interference All Models (excluding SubDrive300) 225300901 Filter (System) Filter used as a system filter on the input and output side of the drive to help eliminate interference SubDrive Utility UT2W 226115910 Filter (System) Filter used as a system filter on the input and output side of the drive to help eliminate interference SubDrive300 225650901 Filter (Surge Capacitors) Capacitor used on the service panel to help eliminate interference All Models 225199901 Heatsink Cover Kit Assists in preventing critters from entering and blocking the fan area All NEMA 4 models (excluding SubDrive300) 225805901 Lightning Arrestor Provides additional surge suppression on the single-phase input power side of the drive All Models 150814902 Low Voltage Kit Used to make adjustments to the input voltage of the SubDrive300 in low voltage applications SubDrive300 225950901 Moisture Sensor Kit External sensor device that shuts down the drive when water is detected All Connect models 226770901 NEMA 1 Fan Replacement Kit Replacement fan (date code prior to 08L) SubDrive75 and MonoDrive NEMA 1 225635905 NEMA 1 Fan Replacement Kit Replacement fan (date code 08L and after) SubDrive75 and MonoDrive NEMA 1 225635908 NEMA 1 Fan Replacement Kit Replacement fan (date code prior to 08K) SubDrive100/150 and MonoDrive NEMA 1 225635907 NEMA 1 Fan Replacement Kit Replacement fan (date code 08K and after) SubDrive100/150 and MonoDrive NEMA 1 225635909 NEMA 3R Fan Replacement Kit Replacement fan (date code prior to 08K) SubDrive75 and MonoDrive NEMA 3R 225635907 NEMA 3R Fan Replacement Kit Replacement fan SubDrive2W 225635910 NEMA 3R Fan Replacement Kit Replacement fan (date code 14L and after) SubDrive15 and MonoDrive Connect and NEMA 3R 226545901 NEMA 3R Fan Replacement Kit Replacement fan (date code 14L and after) SubDrive20/30 and MonoDriveXT Connect and NEMA 3R 226545902 NEMA 3R Fan Replacement Kit Replacement fan SubDrive50 Connect 226545903 NEMA 4 ExternalCooling Fan Replacement Kit Replacement External fan SubDrive75 and MonoDrive NEMA 4 225635901 NEMA 4 ExternalCooling Fan Replacement Kit Replacement External fan SubDrive100/150 and MonoDriveXT NEMA 4 225635902 NEMA 4 ExternalCooling Fan Replacement Kit Replacement External fan (includes 2 fans) SubDrive300 225635903 NEMA 4 InternalCooling Fan Replacement Kit Replacement Internal Stirring fan All NEMA 4 models 225635904 NEMA 4 Auxiliary Relay Board Offers Run-Indication Relay (date code 09J and after) All NEMA 4 models(excluding SubDrive300) 225755901 NEMA 4 Option Card Offers Run-Indication Relay and Underload Extended Off-Time Adjustment (date code 09J and after) All NEMA 4 models (excluding SubDrive300) 225880901 Pressure Sensor (High Pressure 75-150 PSI - NSF Rated) Adjusts pressure in the watersystem from 75-150 PSI (2-leaded 10 ft cable included) All Models 225970901 Pressure Sensor (Standard Pressure 25-90 PSI - NSF Rated) Adjusts pressure in the watersystem from 25-80 PSI (2-leaded 10 ft cable included) All Models 223995901 Pressure Sensor/High PressureShut-Off Kit Kit includes pressure sensor (25-80 PSI), high pressure shut-off sensor (100 PSI), and 4-leaded 10 ft cable SubDrive300 225495901 Pressure Sensor InputBoard Replacement Kit Replacement board for drivesthat have experienced a surge on the pressure sensor input All NEMA 3R models (non-Connect) 226540901 Sensor Cable Kit (Indoor) 100 feet of 22 AWG cable (2-leaded) All Models (excluding SubDrive300) 223995902 Sensor Cable Kit (Indoor) 100 feet of 22 AWG cable (4-leaded) SubDrive300 225495902 Sensor Cable Kit (Outdoor) 100 feet of 22 AWG cable (2-leaded) All Models (excluding SubDrive300) 226941901 Sensor Direct Burial Cable Designed to run in an underground trench without conduit All Models - 10 ft (3 m) 225800901 All Models - 30 ft (9 m) 225800902 All Models - 100 ft (30 m) 225800903 Tank Drawdown Kit Allows the use of water stored in the during low flow demands SubDrive15/20/30/50 and MonoDrive/MonoDriveXT Connect, SubDrive2W, and SubDrive300 225770901 Tank Drawdown Kit Allows the use of water stored in the during low flow demands SubDrive75/100/150 and MonoDrive/MonoDriveXT NEMA 4 (requires Auxiliary Relay Board or NEMA 4 Option Card kit) 225770901 - *N1 = NEMA 1 (Indoors), N3R = NEMA 3R (Indoor/Outdoor), N4 = NEMA 4 (Outdoor)
MonoDrive
MonoDrive (NEMA 3R)
Model 5870205003CMonoDrive (NEMA 4)
Model 5870203114Input from
Power SourceVoltage 208/230 VAC 190-260 VAC Phase In Single-phase Single-phase Frequency 60/50 Hz 60/50 Hz Current (max) 5.7 Amps (RMS) 1/2 hp, 0.37 kW system
8.7 Amps (RMS) 3/4 hp, 0.55 kW system
11 Amps (RMS) 1 hp, 0.75 kW system5.7 Amps (RMS) 1/2 hp, 0.37 kW system
8.7 Amps (RMS) 3/4 hp, 0.55 kW system
11 Amps (RMS) 1 hp, 0.75 kW systemPower Factor ~ 0.95 1.0 (constant) Power (idle) 4 Watts 35 Watts Power (max) 2500 Watts 1150 Watts (1/2 hp, 0.37 kW) system
1750 Watts (3/4 hp, 0.55 kW) system
2150 Watts (1 hp, 0.75 kW) systemWire Gauge Size(s) Consult Federal, State, and Local codes
for branch circuit installationsConsult Federal, State, and Local codes
for branch circuit installationsOutput to Motor Voltage Adjusts with Frequency Adjusts with Frequency Phase Out Single-phase (3-wire) Single-phase (3-wire) Frequency Range 30-63 Hz 30-60 Hz Current (max) Main Phase: 6 Amps (RMS) 1/2 hp, 0.37 kW system
Main Phase: 8 Amps (RMS) 3/4 hp, 0.55 kW system
Main Phase: 10.4 Amps (RMS) 1 hp, 0.75 kW systemMain Phase: 6 Amps (RMS) 1/2 hp, 0.37 kW system
Main Phase: 8 Amps (RMS) 3/4 hp, 0.55 kW system
Main Phase: 10.4 Amps (RMS) 1 hp, 0.75 kW systemWire Gauge Size(s) #6 - #14 * ga. #6 - #18 * ga. Pressure Setting Factory Preset 50 psi (3.4 bar) 50 psi (3.4 bar) Adjustment Range 25-80 psi (1.7 - 5.5 bar) 25-80 psi (1.7 - 5.5 bar) Operating
Conditions(A)Temperature
(at 230 VAC input)-13 °F to 122 °F (-25 °C to 50 °C) -13 °F to 125 °F (-25 °C to 50 °C) Relative Humidity 20-95%, non-condensing 0-100%, condensing Controller Size(B)
(approximate)Outer Dimensions 9-3/4” x 16-3/4” x 5-1/4”
(25 x 42.5 x 13 cm)17-1/2” x 16-3/8” x 11-3/8”
(44.45 x 41.59 x 28.89 cm)Controller Size(B)
(approximate)Weight 20 lbs (9 kg) 24.14 lbs (10.95 kg) For Use With(C) Pump (60 Hz) 0.5 hp (0.37 kW) pump with 214505-series motor
0.75 hp (0.55 kW) pump with 214507-series motor
1.0 hp (0.75 kW) pump with 214508-series motor0.5 hp (0.37 kW) pump with 214505-series motor
0.75 hp (0.55 kW) pump with 214507-series motor
1.0 hp (0.75 kW) pump with 214508-series motorFE Motor 214505-series (0.5 hp, 0.37 kW) single-phase, 3-wire
214507-series (0.75 hp, 0.55 kW) single-phase, 3-wire
214508- series (1.0 hp, 0.75 kW) single-phase, 3-wire214505-series (0.5 hp, 0.37 kW) single-phase, 3-wire
214507-series (0.75 hp, 0.55 kW) single-phase, 3-wire (default)
214508- series (1.0 hp, 0.75 kW) single-phase, 3-wire- Notes: Refer to Franklin Electric’s SubDrive/MonoDrive Installation Manual.
- (A) Operating temperature is specified at full output power when installed as described in Controller Location Selection.
- (B) Refer to detailed Mounting Dimensions.
- (C) If a pump other than the default rating is used, refer to Drive Configuration.
- * Refer to detailed Circuit Breaker and Wire Sizing charts.
MonoDriveXT
MonoDriveXT (NEMA 3R)
Model 5870205203CMonoDriveXT (NEMA 4)
Model 5870204114Input from
Power SourceVoltage 208/230 VAC 190-260 VAC Phase In Single-phase Single-phase Frequency 60/50 Hz 60/50 Hz Current (max) 13 Amps (RMS) 1.5 hp, 1.1 kW system 13 Amps (RMS) 1.5 hp, 1.1 kW system 16 Amps (RMS) 2 hp, 1.5 kW system 16 Amps (RMS) 2 hp, 1.5 kW system Power Factor ~ 0.95 1.0 (constant) Power (idle) 5 Watts 65 Watts Power (max) 4200 Watts 2500 Watts (1.5 hp, 1.1 kW) system 3100 Watts (2 hp, 1.5 kW) system Wire Gauge Size(s) Consult Federal, State, and
Local codes for branch
circuit installationsConsult Federal, State, and
Local codes for branch
circuit installationsOutput to Motor Voltage Adjusts with Frequency Adjusts with Frequency Phase Out Single-phase (3-wire) Single-phase (3-wire) Frequency Range 30-63 Hz 30-60 Hz Current (max) Main Phase: 11.5 Amps (RMS) 1.5 hp, 1.1 kW system
Main Phase: 13.2 Amps (RMS) 2 hp, 1.5 kW systemMain Phase: 11.5 Amps (RMS) 1.5 hp, 1.1 kW system
Main Phase: 13.2 Amps (RMS) 2 hp, 1.5 kW systemWire Gauge Size(s) #6 - #14 * ga. #6 - #18 * ga. Pressure Setting Factory Preset 50 psi (3.4 bar) 50 psi (3.4 bar) Adjustment Range 25-80 psi (1.7 and 5.5 bar) 25-80 psi (1.7 - 5.5 bar) Operating
Conditions(A)Temperature
(at 230 VAC input)-13 °F to 122 °F (-25 °C to 50 °C) -13 °F to 125 °F (-25 °C to 50 °C) Relative Humidity 20-95%, non-condensing 0-100%, condensing Controller Size(B)
(approximate)Outer Dimensions 9-3/4” x 19-3/4” x 5-1/4”
(25 x 50 x 13 cm)17-1/2” x 16-3/8” x 11-3/8”
(44.45 x 41.59 x 28.89 cm)Weight 26 lbs (11.8 kg) 28.32 lbs (12.84 kg) For Use With(C) Pump (60 Hz) 1.0 hp (0.75 kW) pump with 214508-series motor
1.5 hp (1.1 kW) pump with 224300-series motor
2.0 hp (1.5 kW) pump with 224301-series motor1.0 hp (0.75 kW) pump with 214508-series motor
1.5 hp (1.1 kW) pump with 224300-series motor
2.0 hp (1.5 kW) pump with 224301-series motorFE Motor 214508-series (1.0 hp, 0.75 kW) single-phase, 3-wire
224300-series (1.5 hp, 1.1 kW) single-phase, 3-wire
224301-series (2.0 hp, 1.5 kW) single-phase, 3-wire214508-series (1.0 hp, 0.75 kW) single-phase, 3-wire
224300-series (1.5 hp, 1.1 kW) single-phase, 3-wire (default)
224301-series (2.0 hp, 1.5 kW) single-phase, 3-wire- Notes: Refer to Franklin Electric’s SubDrive/MonoDrive Installation Manual.
- (A) Operating temperature is specified at full output power when installed as described in Controller Location Selection.
- (B) Refer to detailed Mounting Dimensions.
- (C) If a pump other than the default rating is used, refer to Drive Configuration.
- * Refer to detailed Circuit Breaker and Wire Sizing charts.
SubDrive15 and SubDrive20
SubDrive15 (NEMA 3R) (D) SubDrive20 (NEMA 3R) (D) Model No. Indoor/Outdoor Model 5870205103C Model 5870205303C Input from
Power SourceVoltage 208/230 VAC 208/230 VAC Phase In Single-phase Single-phase Frequency 60/50 Hz 60/50 Hz Current (max) 12 Amps 19 Amps Power Factor ~ 0.95 ~ 0.95 Power (idle) 4 Watts 5 Watts Power (max) 2500 Watts 4200 Watts Wire Gauge Size(s) Consult Federal, State,
and Local codes for branch
circuit installationsConsult Federal, State,
and Local codes for branch
circuit installationsOutput to
MotorVoltage Adjusts with Frequency Adjusts with Frequency Phase Out Single-phase (3-wire) OR Three-phase Single-phase (3-wire) OR Three-phase Frequency Range 30-77 Hz (3/4 hp, 0.55 kW) pump
30-72 Hz (1 hp, 0.75 kW) pump
30-60 Hz (1.5 hp, 1.1 kW) pump
30-63 Hz (Single-phase Motors)30-78 Hz (1hp, 0.75 kW) pump
30-72 Hz (1.5 hp, 1.1 kW) pump
30-60 Hz (2 hp, 1.5 kW) pump
30-63 Hz (Single-phase Motors)Current (max) 5.9 A / phase 8.1 A / phase Wire Gauge Size(s) #6 - #14 * ga. #6 - #14 * ga. Pressure Setting Factory Preset 50 psi (3.4 bar) 50 psi (3.4 bar) Adjustment Range 25-80 psi (1.7 - 5.5 bar) 25-80 psi (1.7 - 5.5 bar) Operating
Conditions(A)Temperature
(at 230 VAC input)-13 °F to 122 °F (-25 °C to 50 °C) -13 °F to 122 °F (-25 °C to 50 °C) Relative Humidity
(NEMA 3R)20-95%, non-condensing 20-95%, non-condensing Controller Size(B)
(approximate)Outer Dimensions
Weight9-3/4” x 19-3/4” x 5-1/4”
(25 x 50 x 13 cm)
26 lbs (11.8 kg)9-3/4” x 19-3/4” x 5-1/4”
(25 x 50 x 13 cm)
26 lbs (11.8 kg)For Use With(C) Pump (60 Hz) 0.5 hp (0.37 kW) pump with
214505-series motor
0.75 hp (0.55 kW) pump with
214507-series motor
1.0 hp (0.75 kW) pump with
214508-series motor
0.75 hp (0.55 kW), 1.0 hp
(0.75 kW) 1.5 hp (1.1 kW) pump
with 234514-series motor1.0 hp (0.75 kW) pump
with 214508-series motor
1.5 hp (1.1 kW) pump
with 224300-series motor
2.0 hp (1.5 kW) pump
with 224301-series motor
0.75 hp (0.55 kW), 1.0 hp
(0.75 kW), 1.5 hp (1.1 kW) pump
with 234514-series motor
1.0 hp (0.75 kW), 1.5 hp (1.1 kW),
2.0 hp (1.5 kW) pump
with 234315-series motorFE Motor 214505-series
(0.5 hp, 0.37 kW) single-phase,
3-wire 214507-series
(0.75 hp, 0.55 kW)
single-phase, 3-wire 214508-series
(1.0 hp, 0.75 kW)
single-phase, 3-wire 234514-series
(1.5 hp, 1.1 kW) three-phase214508-series (1.0 hp, 0.75 kW)
single-phase, 3-wire
224300-series (1.5 hp, 1.1 kW)
single-phase, 3-wire
224301-series (2.0 hp, 1.5 kW)
single-phase, 3-wire
234514-series (1.5 hp, 1.1 kW)
three-phase
234315-series (2.0 hp, 1.5 kW)
three-phase- Notes: Refer to Franklin Electric’s SubDrive/MonoDrive Installation Manual.
- (A) Operating temperature is specified at full output power when installed as described in Controller Location Selection.
- (B) Refer to detailed Mounting Dimensions.
- (C) If a pump other than the default rating is used, refer to Drive Configuration.
- (D) When operating a SubDrive as a MonoDrive, the MonoDrive NEMA 3R pump and motor specifications in the manual apply.
- * Refer to detailed Circuit Breaker and Wire Sizing charts.
SubDrive30 and SubDrive75
SubDrive30 (NEMA 3R) (D)
Model 5870205403CSubDrive75 (NEMA 4)
Model 5870203384Input from
Power SourceVoltage 208/230 VAC 190-260 VAC Phase In Single-phase Single-phase Frequency 60/50 Hz 60/50 Hz Current (max) 23 Amps 11 Amps (RMS) Power Factor ~ 0.95 1.0 (constant) Power (idle) 5 Watts 35 Watts Power (max) 4.2 kW 2400 Watts Wire Gauge Size(s) Consult Federal, State,
and Local codes for branch
circuit installationsConsult Federal, State,
and Local codes for branch
circuit installationsOutput to Motor Voltage Adjusts with Frequency Adjusts with Frequency Phase Out Single-phase (3-wire) OR Three-phase Three-Phase (3-wire) Frequency Range 30-78 Hz (1.5 hp, 1.1 kW) pump 30-80 Hz (3/4 hp, 0.55 kW) pump 30-70 Hz (2 hp, 1.5 kW) pump 30-70 Hz (1 hp, 0.75 kW) pump 30-60 Hz (3 hp, 2.2 kW) pump 30-60 Hz (1.5 hp, 1.1 kW) pump 30-63 Hz (Single-Phase Motors) Current (max) 10.9 A / phase 5.9 Amps (RMS, each phase) Wire Gauge Size(s) #6 - #14 * ga. #6 - #18 * ga. Pressure Setting Factory Preset 50 psi (3.4 bar) 50 psi (3.4 bar) Adjustment Range 25-80 psi (1.7 - 5.5 bar) 25-80 psi (1.7 and 5.5 bar) Operating
Conditions(A)Temperature
(at 230 VAC input)-13 °F to 122 °F (-25 °C to 50 °C) -13 °F to 125 °F (-25 °C to 50 °C) Relative Humidity 20-95%, non-condensing 0-100%, condensing Controller Size(B)
(approximate)Outer Dimensions 9-3/4” x 19-3/4” x 5-1/4” 17-1/2” x 16-3/8” x 11-3/8” (44.45 x 41.59 x 28.89 cm) Weight (25 x 50 x 13 cm) 24.14 lbs (10.95 kg) 26 lbs (11.8 kg) For Use With(C) Pump (60 Hz) 1.0 hp (0.75 kW) pump
with 214508-series motor
1.5 hp (1.1 kW) pump
with 224300-series motor
2.0 hp (1.5 kW) pump
with 224301-series motor
0.75 hp (0.55 kW), 1.0 hp
(0.75 kW), or 1.5 hp (1.1 kW)
pump with 234514-series motor
1.0 hp (0.75 kW), 1.5 hp (1.1 kW),
or 2.0 hp (1.5 kW) pump
with 234315-series motor
1.5 hp (1.1 kW), 2.0 hp (1.5 kW),
or 3.0 hp (2.2 kW) pump with
234316-series motor3/4 hp (0.55 kW) [default]
1 hp (0.75 kW)
1.5 hp (1.1 kW)FE Motor 214508-series (1.0 hp, 0.75 kW)
single-phase, 3-wire
224300-series (1.5 hp, 1.1 kW)
single-phase, 3-wire
224301-series (2.0 hp, 1.5 kW)
single-phase, 3-wire
234514-series (1.5 hp, 1.1 kW) three-phase
234315-series (2.0 hp, 1.5 kW) three-phase
234316-series (3.0 hp, 2.2 kW) three-phase234514 - series (1.5 hp, 1.1 kW) - Notes: Refer to Franklin Electric’s SubDrive/MonoDrive Installation Manual.
- (A) Operating temperature is specified at full output power when installed as described in Controller Location Selection.
- (B) Refer to detailed Mounting Dimensions.
- (C) If a pump other than the default rating is used, refer to Drive Configuration.
- (D) When operating a SubDrive as a MonoDrive, the MonoDrive NEMA 3R pump and motor specifications in the manual apply.
- * Refer to detailed Circuit Breaker and Wire Sizing charts.
SubDrive100 and SubDrive150
SubDrive100 (NEMA 4) SubDrive150 (NEMA 4) Model No. Indoor/Outdoor Model 5870204104 Model 5870204154 Input from
Power SourceVoltage 190-260 VAC 190-260 VAC Phase In Single-phase Single-phase Frequency 60/50 Hz 60/50 Hz Current (max) 19 Amps (RMS) 23 Amps (RMS) Power Factor 1.0 (constant) 1.0 (constant) Power (idle) 65 Watts 65 Watts Power (max) 3800 Watts 4600 Watts Wire Gauge Size(s) Consult Federal, State, and Local
codes for branch circuit installationsConsult Federal, State, and Local
codes for branch circuit installationsOutput to Motor Voltage Adjusts with Frequency Adjusts with Frequency Phase Out Three-phase (3-wire) Three-phase (3-wire) Frequency Range 30-80 Hz (1 hp, 0.75 kW) pump 30-80 Hz (1.5 hp, 1.1 kW) pump 30-70 Hz (1.5 hp, 1.1 kW) pump 30-70 Hz (2 hp, 1.5 kW) pump 30-60 Hz (2 hp, 1.5 kW) pump 30-60 Hz (3 hp, 2.2 kW) pump Current (max) 8.1 Amps (RMS, each phase) 10.9 Amps (RMS, each phase) Wire Gauge Size(s) #6 - #18 * ga. #6 - #18 * ga. Pressure Setting Factory Preset 50 psi (3.4 bar) 50 psi (3.4 bar) Adjustment Range 25-80 psi (1.7 - 5.5 bar) 25-80 psi (1.7 - 5.5 bar) Operating
Conditions(A)Temperature
(at 230 VAC input)-13 °F to 125 °F (-25 °C to 50 °C) -13 °F to 125 °F (-25 °C to 50 °C) Relative Humidity 0-100%, condensing 0-100%, condensing Controller Size(B)
(approximate)Outer Dimensions
Weight17-1/2” x 16-3/8” x 11-3/8”
(44.45 x 41.59 x 28.89 cm)
28.32 lbs (12.84 kg)17-1/2" x 16-3/8" x 11-3/8"
(44.45 x 41.59 x 28.89 cm)
28.32 lbs (12.84 kg)For Use With(C) Pump (60 Hz) 1 hp (0.75 kW) [default]
1.5 hp (1.1 kW)
2 hp (1.5 kW)1.5 hp (1.1 kW) [default]
2 hp (1.5 kW)
3 hp (2.2 kW)FE Motor 234315 - series (2 hp, 1.5 kW) 234316 - series (3 hp, 2.2 kW) - Notes: Refer to Franklin Electric’s SubDrive/MonoDrive Installation Manual.
- (A) Operating temperature is specified at full output power when installed as described in Controller Location Selection.
- (B) Refer to detailed Mounting Dimensions.
- (C) If a pump other than the default rating is used, refer to Drive Configuration.
- * Refer to detailed Circuit Breaker and Wire Sizing charts.
SubDrive300 and SubDrive50
SubDrive300 (NEMA 4) SubDrive50 (NEMA 3R) Model No. Indoor/Outdoor Model 5870206300 5870205503C Input from
Power
SourceVoltage 220-260 VAC 208/230 /- 10% VAC Phase In Single-phase Single-phase Frequency 60/50 Hz 60/50 Hz Current (max) 36 Amps (RMS) 36 Amps (RMS) Power Factor 1.0 (constant) 0.95 Power (idle) 65 Watts 7 Watts Power (max) 7200 Watts 7200 Watts Wire Gauge
Size(s)Consult Federal, State,
and Localcodes for
branch circuit installationsConsult Federal, State, and Local
codes for branch circuit installationsOutput
to MotorVoltage Adjusts with Frequency Variable based on frequency Phase Out Three-phase (3-wire) Single-phase (3-wire) OR three-phase Frequency
Range30-80 Hz
(3 hp, 2.2 kW) pump
30-70 Hz
(5 hp, 3.7 kW) pump30-78 Hz: 1/2-rated mismatched pump with three-phase motor
30-70 Hz: 2/3 or 3/4-rated mismatched pump with three-phase motor
30-60 Hz: Matched pump with three-phase motor
30-63 Hz: Matched pump with single-phase motorCurrent (max) 17.8 Amps (RMS, each phase) 17.8 A (three-phase), 17.0 A (single-phase) Wire Gauge
Size(s)#2 - #18 * ga. #6 - #12 * ga. Pressure
SettingFactory preset 50 psi (3.4 bar) 50 psi (3.4 bar) Adjustment
Range25-80 psi (1.7 - 5.5 bar) Analog Transducer: 5-95 psi (0.3 - 6.6 bar)
Pressure Sensor: 25-80 psi (1.7 - 5.5 bar)Operating
Conditions(A)Temperature
(@ 230 VAC input)-13 °F to 125 °F
(-25 °C to 50 °C)-13 °F to 122 °F
(-25 °C to 50 °C)Relative
Humidity0-100%, condensing 20-95%, non-condensing Controller
Size(B)
(approximate)Outer
Dimensions
Weight19-7/8” x 17-1/2” x 14-1/4”
(50.48 x 44.45 x 36.20 cm)
35.15 lbs (15.94 kg)26 1/8" x 15 3/8" x 11 1/2"
(66 x 39 x 29 cm)
31 lbs (14.1 kg)For Use
With(C)Pump (60 Hz) 3 hp (2.2 kW) [default]
5 hp (3.7 kW)0.5 hp (0.37 kW) pump with 214505-series motor
0.75 hp (0.55 kW) pump with 214507-series motor
1.0 hp (0.75 kW) pump with 214508-series motor
1.5 hp (1.1 kW) pump with 224300-series motor
2.0 hp (1.5 kW) pump with 224301-series motor
3.0 hp (2.2 kW) pump with 224302-series motor
0.5hp (0.37 kW), 0.75 hp (0.55 kW), or 1.0 hp (0.75 kW) pump w/ 234513-series motor
0.75 hp (0.55 kW), 1.0 hp (0.75 kW), or 1.5 hp (1.1 kW) pump w/ 234514-series motor
1.0 hp (0.75 kW), 2.0 hp (1.5 kW), or 2.0 hp (1.5 kW) pump w/ 234315-series motor
1.5 hp (1.1 kW), 2.0 hp (1.5 kW), or 3.0 hp (2.2 kW) pump w/ 234316-series motor
3.0 hp (2.2 kW) or 5.0 hp (3.7 kW) pump w/ 234317-series motorFE Motor 234317-series
(5 hp, 3.7 kW)214505-series (0.5hp, 0.37 kW) single-phase, 3-wire
214507-series (0.75hp, 0.55 kW) single-phase, 3-wire
214508-series (1.0 hp, 0.75 kW) single-phase, 3-wire
224300-series (1.5 hp, 1.1 kW) single-phase, 3-wire
224301-series (2.0 hp, 1.5 kW) single-phase, 3-wire
224302-series (3.0 hp, 2.2 kW) single-phase, 3-wire
234513-series (1.0 hp, 0.75 kW) three-phase
234514-series (1.5 hp, 1.1 kW) three-phase
234315-series (2.0 hp, 1.5 kW) three-phase
234316-series (3.0 hp, 2.2 kW) three-phase
234317-series (5.0 hp, 3.7 kW) three-phase- Notes: Refer to Franklin Electric’s SubDrive/MonoDrive Installation Manual.
- (A) Operating temperature is specified at full output power when installed as described in Controller Location Selection.
- (B) Refer to detailed Mounting Dimensions.
- (C) If a pump other than the default rating is used, refer to Drive Configuration.
- * Refer to detailed Circuit Breaker and Wire Sizing charts.
SubDrive2W
SubDrive2W (NEMA 3R) Model No. Indoor/Outdoor Model 5870203223 Input from
Power SourceVoltage 207-260 VAC Phase In Single-phase Frequency 60/50 Hz Current (max) 14 Amps (RMS) (For circuit breaker sizing) Power Factor 0.7 (approximate) Power (idle) 20 Watts Power (max) 1900 Watts Wire Gauge Size(s) Consult Federal, State, and Local
codes for branch circuit installationsOutput to Motor Voltage Adjusts with Frequency Phase Out Single-phase (2-wire) Frequency Range 30-60 Hz Current (max) 6 Amps (RMS) 1/2 hp, 0.37 kW system
8 Amps (RMS) 3/4 hp, 0.55 kW system
10.4 Amps (RMS) 1 hp, 0.75 kW systemWire Gauge Size(s) #6 - #18 * ga. Pressure Setting Factory preset 50 psi (3.4 bar) Adjustment Range 25-80 psi (1.7 - 5.5 bar) Operating
Conditions(A)Temperature
(at 230 VAC input)-13 °F to 125 °F (-25 °C to 50 °C) Relative Humidity 10-95%, non-condensing Controller Size(B)
(approximate)Outer Dimensions
Weight12-1/4” x 16-1/2” x 9”
(31.1 x 41.9 x 22.9 cm)
15.0 lbs (6.80 kg)For Use With(C) Pump (60 Hz) 1/2 hp pump/motor with 244505-series
3/4 hp pump/motor with 244507-series [default]
1 hp pump/motor with 244508-seriesFE Motor Not Available - Notes: Refer to Franklin Electric’s SubDrive/MonoDrive Installation Manual.
- (A) Operating temperature is specified at full output power when installed as described in Controller Location Selection.
- (B) Refer to detailed Mounting Dimensions.
- (C) If a pump other than the default rating is used, refer to Drive Configuration.
- * Refer to detailed Circuit Breaker and Wire Sizing charts.
-
Brochures
-
Agricultural Solutions Brochure (M5068)
-
Lake And Pond Management Brochure (M5064)
-
Agricultural Solutions Brochure - Spanish (M5068sp)
-
Drive Family Comparison (M1786)
-
SubDrive Connect Sell Sheet - Spanish (M1762sp)
-
SubDrive Connect Sell Sheet (M1762)
-
Duplex Alternator Brochure (M1561)
-
SubDrive Family Brochure -Spanish (M1459sp)
-
SubDrive Family Brochure (Portuguese)
-
SubDrive Family Brochure - French (M1459fr)
-
SubDrive Family Brochure (M1459)
-
Electronics Manufacturing Brochure (M5075)
-
SubDrive Connect Training Tool (M5070)
Manuals
-
2015 60 Hz AIM Manual
-
Forms 2207 Submersible Motor Install Record
-
60 Hz AIM Manual (Spanish)
-
60 Hz AIM Manual Addendum (M1311A)
-
60Hz AIM Manual Addendum (M1311A sp) Spanish
-
60Hz AIM Manual Addendum (M1311A fr) French
-
SubDrive NEMA 1 and NEMA 4 Owner's Manual (M1560)
-
SubDrive NEMA 3R Owner's Manual
-
SubDrive/Monodrive Connect Owners Manual (226203103)
Kit Information
-
IGF Input Filter Manual (226035102)
-
AMR Input Filter Manual (226030102)
-
Duplex Alternator Manual (225589101) (Trilingual)
-
NEMA 4 Option Card Manual (English)
-
SubDrive50 Connect Fan Replacement Install Guide (226546103)
-
SD/MD Connect Fan Replacement Install Guide (226546102)
-
EMI Input Filter Install Guide (225214101)
-
EMI Output Filter Install Guide (225463101)
-
CE Input Filter Install Guide (226788101)
-
Enhanced Sensor Board Replacement Install Guide (226541102)
-
Enhanced Display Board Replacement Install Guide (226541112)
-
Display Board Replacement Install Guide (226541111)
-
SubDrive300 Internal Stirring Fan Replacement Installation Guide (225661101)
-
SubDrive300 External Cooling Fan Replacement Installation Guide (225657101)
-
SubDrive2W Fan Replacement Kit Installation Guide (225851101)
-
NEMA 1 Fan Replacement Kit Installation Guide (225715101)
-
SubDrive NEMA 3R Pressure Input Board Replacement Kit Installation Guide (226541101)
-
NEMA 4 External Cooling Fan Replacement Installation Guide (225621101)
-
SubDrive50 Connect Air Screen Kit Install Guide (226551102)
-
SubDrive NEMA 3R Air Screen Kit Installation Guide (226551101)
-
NEMA 3R Fan Replacement Kit Installation Guide (226546101)
-
Tank Drawdown Kit Installation Guide (225767101)
-
Moisture Sensor Install Guide (226770101)
-
High Pressure Sensor Kit (225970101)
-
SubDrive2w Air Filter Install Guide (225835901)
-
SubDrive NEMA4 Heatsink Cover Kit Install Guide (225804101)
-
Aux Relay Install Manual (22573110)
-
SubDrive Filter Install Guide (225671101)
-
Lightning Arrestor Manual (225594101)
-
SubDrive300 Pressure Sensor Kit Manual (225404101)
-
CP Water Surge Capacitor Install Manual (225216101)
-
SubDrive Connect Bug Screen Kit (22446910)
-
SubDrive Pressure Sensor Kit Manual (223991101)
-