SubDrive/MonoDrive

SubDrive/MonoDrive

Constant Pressure Variable Frequency Drives (VFD)

Franklin Electric’s constant pressure controllers use state-of-the-art technology to provide constant water pressure through variable speed control of submersible water well pumps.

Applications

  • Residential homes
  • Restaurants
  • Farms
  • Schools
  • Car washes
  • Landscape irrigation systems
Features
Order Info
Specs & Accessories
Downloads
  • Benefits

    • Constant water pressure with a wide range of settings
    • Single-phase input power
    • Easy, plug-and-play installation
    • Smooth running
    • High starting torque
    • Soft-start feature prevents water hammer and increases motor life
    • Works with small pressure tanks or existing larger tanks
    • Advanced filtering to remove radio frequency interference
    • Easily replaceable fan kit
    • NEMA 3R and NEMA 4 (indoor/outdoor) enclosure options
    • UL and cUL listed
    • Built-in diagnostics and protection
    • Surge Protection
    • Short circuit
    • Underload
    • Overheated controller
    • Undervoltage
    • Broken pipe detection (SubDrive Connect only)
    • Locked pump
    • User-configurable underload off time (SubDrive Connect only)
    • Open circuit

    SubDrive Connect

    Franklin Electric’s selection of SubDrive15, SubDrive20, SubDrive30 and SubDrive50 controllers use state-of-the-art technology to provide constant water pressure through variable speed control of submersible water well pumps including connectivity for advanced monitoring, setup and troubleshooting through FE Connect mobile app.

    • Single-phase input, 3-wire and three-phase motor control
    • 1/2 – 5 hp performance in an array of submersible and above ground pumping systems
    • FE Connect Smartphone app for advanced settings, monitoring and troubleshooting
    • User-configurable motor frequency range
    • NEMA 3R enclosure (indoor/outdoor) that provides a degree of protection against falling rain or sleet

    SubDrive (NEMA 4)

    SubDrive75, SubDrive100, SubDrive150, and SubDrive300 controllers are designed for three phase motors to provide constant pressure with three-phase performance using single-phase input power. Designed within a NEMA 4 weatherproof enclosure, they offer rugged, watertight variable frequency drive solutions that meets water demand changes.

    • Single-phase input, 3-phase motor control
    • 1-1/2 – 5 hp performance
    • NEMA 4 enclosure (indoor/outdoor) offers robust protection against harsh environmental conditions

    MonoDrive and MonoDrive XT (NEMA 4)

    MonoDrive and MonoDriveXT are designed to convert a conventional ½ hp to 2 hp pump system to a variable speed constant pressure system by simply replacing the 3-wire control box and pressure switch.

    • Single-phase input, 3-wire motor control
    • ½ hp to 2 hp performance
    • NEMA 4 enclosure (indoor/outdoor) offers robust protection against harsh environmental conditions

    Franklin Drive Family Comparison

    Submersible Motors
    PhaseVoltsHorsepowerQD
    Pumptec
    PumptecPumptec
    Plus
    SubDrive Utility
    UT2W
    SubDrive Utility
    UT3P
    MonoDrive/
    MonoDriveXT
    NEMA 4
    SubDrive
    75/100/150/300
    NEMA 4
    SubDrive
    15/20/30/50
    Connect
    1-Phase
    2-Wire
    115 V1/3 - 1/2 hpxx
    230 V1/3 - 1.5 hpxxx
    1-Phase
    3-Wire
    115 V1/3 - 1/2 hpxx
    230 V1/3 hpxxx
    1/2 - 1 hpxxxxxx
    1.5 hpxxxxx
    2 hpxxxx
    3 hpxx
    5 hpx
    3-Phase230 V1 hp - 2 hpxx
    1.5 hp - 5 hpxx
    Surface Pumps
    PhaseVolts/
    Horsepower
    QD
    Pumptec
    PumptecPumptec
    Plus
    SubDrive
    Utility
    SubDrive
    Utility UT3P
    MonoDrive/
    MonoDriveXT
    NEMA 4
    SubDrive
    75/100/150/300
    NEMA 4
    SubDrive
    15/20/30/50
    Connect
    1-Phase
    2-Wire
    115V, 1/3 - 1 hpx
    230V, 1/3 - 2 hpx
    3-Phase230V, 1/2 - 2 hpxx
    230V, 3 - 5 hpx
    Features and Protection
    SpecificationsQD
    Pumptec
    PumptecPumptec
    Plus
    SubDrive
    Utility
    SubDrive
    Utility UT3P
    MonoDrive/
    MonoDriveXT
    NEMA 4
    SubDrive
    75/100/150/300
    NEMA 4
    SubDrive
    15/20/30/50
    Connect
    FeaturesConstant Pressurexxxxx
    ProtectionRatingNEMA 3RNEMA 3RNEMA 3RNEMA 3RNEMA 4NEMA 4NEMA 3R
    Underloadxxxxxxxx
    Undervoltagexxxxxxxx
    Overvoltagexxxxxxxx
    Rapid CyclexxSoft StartSoft StartSoft StartSoft Start
    Overload / Locked
    Pump
    xxxxxxxx
    Open Circuitxxxxx
    Short Circuitxxxxx
    Phase Imbalancex
    Input/
    Output/
    Control
    Pressure
    Sensor (Hobbs)
    xxxxx
    Pressure
    Transducer (4-20mA)
    xxx
    Run Relay OutputAccessoryAccessory or
    SubDrive300
    x
    Fault Relay OutputSubDrive300x
    Broken Pipexxx
    Pressure Sensor Errorxxx
    Auxiliary Controlx
    Wet Floor Sensorx
    Built-In Duplex
    Alternator
    x
    Mobile App Advanced
    Configuration
    x
    Diagnostic
    Fault History
    x
    Real-Time Monitoringx
  • NEMA 3R Constant Pressure Controllers

    VFDEnclosure TypeModel No.
    SubDrive15 Connect NEMA 3R, VARIABLE FREQUENCY5870205103C
    SubDrive20 Connect NEMA 3R, VARIABLE FREQUENCY5870205303C
    SubDrive30 Connect NEMA 3R, VARIABLE FREQUENCY5870205403C
    SubDrive50 Connect NEMA 3R, VARIABLE FREQUENCY5870205503C
    • NEMA 3R enclosure (indoor/outdoor) that provides a degree of protection against falling rain or sleet

    NEMA 4 Constant Pressure Controllers

    VFDEnclosure TypeModel No.
    MonoDrive NEMA 4 VARIABLE FREQUENCY5870203114
    MonoDriveXT NEMA 4 VARIABLE FREQUENCY5870204114
    SubDrive 75 NEMA 4, VARIABLE FREQUENCY5870203384
    SubDrive 100 NEMA 4, VARIABLE FREQUENCY5870204104
    SubDrive 150 NEMA 4, VARIABLE FREQUENCY5870204154
    SubDrive 300 NEMA 4, VARIABLE FREQUENCY5870206300
    • NEMA 4 enclosure (indoor/outdoor) offers robust protection against harsh environmental conditions
  • SubDrive/MonoDrive Accessories

    AccessoriesDetailUsed WithPart No.
    Air Screen KitHelps prevent insects from entering and damaging the internal components of the driveSubDrive15/20/30 Connect and MonoDrive/XT Connect (date code 18A and older)226550901
    SubDrive50 Connect (date code 18A and older)226550902
    Replacement kit for the included standard with SubDrive/
    MonoDrive Connect models built February 2018 and after
    SubDrive15/20/30/50 Connect and MonoDrive/MonoDriveXT Connect (date code 18B and newer)575214902
    Analog Pressure Transducer4-20mA analog pressure transducer (includes 10 ft cable)All Connect and Utility Models - 100 PSI226905902
    All Connect and Utility Models - 150 PSI226905903
    All Connect and Utility Models - 200 PSI226905904
    Analog PressureTransducer Cable KitOutdoor rated cable to connect analog pressure transducer to the driveAll Connect and Utility models - 10 ft226910901
    All Connect and Utility models - 25 ft226910902
    All Connect and Utility models - 50 ft226910903
    All Connect and Utility models - 100 ft226910904
    All Connect and Utility models - 150 ft226910905
    All Connect and Utility models - 200 ft226910906
    Duplex AlternatorAllows a water system to alternate between two parallel pumps controlled by separate drives. All Models5850012000
    Must use pressure sensor; not compatible with analog pressure transducer
    Duplex Alternator Cable KitCommunication cable kit required to use built-in Duplex
    Alternator function in drives equipped with this feature
    All Connect models - 10 ft226895901
    All Connect models - 50 ft226895902
    All Connect models - 100 ft226895903
    Enhanced Display Board Replacement KitReplacement for drives with damaged display, battery holder, or Duplex Alternator communication issueAll Connect models226540912
    Enhanced Pressure Input Board Replacement KitReplacement board for drives that have experienced a surge on the control inputsAll Connect models226540902
    Filter (Input)Filter used on the input side of the drive to help eliminate interferenceAll Models225198901
    Filter (Input AMR)Filter used on the input side of the drive to help eliminate
    interference with automated meter reading systems.
    All models (excluding SubDrive30/50,
    SubDrive150, and SubDrive300)
    226030901
    Filter (Input IGF)Filter used in the input side of the drive to help eliminate interference on the ground wireAll models226035901
    Filter (Output)Filter used on the output side of the drive to help eliminate interferenceAll Models (excluding SubDrive300)225300901
    Filter (Surge Capacitors)Capacitor used on the service panel to help eliminate interferenceAll Models225199901
    Heatsink Cover KitAssists in preventing critters from entering and blocking the fan areaAll NEMA 4 models (excluding SubDrive300)225805901
    Lightning ArrestorProvides additional surge suppression on the single-phase input power side of the driveAll Models150814902
    Low Voltage KitMake adjustments to the input voltage of the SubDrive300 in low voltage applicationsSubDrive300225950901
    Moisture Sensor KitExternal sensor device that shuts down the drive when water is detectedAll Connect models226770901
    NEMA 3R Fan Replacement KitReplacement FanSubDrive50 Connect226545903
    Replacement fan (date code prior to 08K)SubDrive75 and MonoDrive NEMA 3R225635907
    Replacement fan (date code 14L and after)SubDrive15, MonoDrive Connect and NEMA 3R226545901
    Replacement fan (date code 14L and after)SubDrive20/30, MonoDriveXT Connect and NEMA 3R226545902
    NEMA 4 Cooling Fan Replacement KitReplacement External fanSubDrive75 and MonoDrive NEMA 4225635901
    SubDrive100/150 and MonoDriveXT NEMA 4225635902
    Replacement External fan (includes 2 fans)SubDrive300225635903
    Replacement Internal Stirring fanAll NEMA 4 models225635904
    NEMA 4 Auxiliary Relay BoardOffers Run-Indication Relay (date code 09J and after)All NEMA 4 models(excluding SubDrive300)225755901
    NEMA 4 Option CardOffers Run-Indication Relay and Underload Extended
    Off-Time Adjustment (date code 09J and after)
    All NEMA 4 models (excluding SubDrive300)225880901
    Pressure SensorHigh Pressure 75-150 PSI - NSF Rated
    Adjusts pressure in the watersystem from 75-150 PSI (2-leaded 10 ft cable included)
    All Models225970901
    Standard Pressure 25-90 PSI - NSF Rated
    Adjusts pressure in the watersystem from 25-80 PSI (2-leaded 10 ft cable included)
    All Models223995901
    Pressure Sensor/High Pressure Shut-Off KitIncludes pressure sensor (25-80 PSI), high pressure shut-off sensor (100 PSI), and 4-leaded 10 ft cableSubDrive300225495901
    Pressure Sensor Input Board Replacement KitReplacement board for drivesthat have experienced a surge on the pressure sensor inputAll NEMA 3R models (non-Connect)226540901
    Sensor Cable KitIndoor, 100 feet of 22 AWG cable (2-leaded)All Models (excluding SubDrive300)223995902
    Indoor, 100 feet of 22 AWG cable (4-leaded)SubDrive300225495902
    Outdoor, 100 feet of 22 AWG cable (2-leaded)All Models (excluding SubDrive300)226941901
    Sensor Direct Burial CableDesigned to run in an underground trench without conduitAll Models - 10 ft (3 m)225800901
    All Models - 30 ft (9 m)225800902
    All Models - 100 ft (30 m)225800903
    Tank Drawdown KitAllows the use of water stored in the during low flow demandsSubDrive15/20/30/50 and MonoDrive/MonoDriveXT Connect, and SubDrive300225770901
    SubDrive75/100/150 and MonoDrive/MonoDriveXT NEMA 4 (requires Auxiliary Relay Board or NEMA 4 Option Card kit)225770901
    • N3R = NEMA 3R (Indoor/Outdoor), N4 = NEMA 4 (Outdoor)

    SubDrive15 and SubDrive20

    NEMA 3RSubDrive15SubDrive20
    Indoor/OutdoorModel No.5870205103C5870205303C
    Input from
    Power Source
    Voltage208/230 VAC208/230 VAC
    Phase InSingle-phaseSingle-phase
    Frequency60/50 Hz60/50 Hz
    Current (max)12 Amps19 Amps
    Power Factor~ 0.95~ 0.95
    Power (idle)4 Watts5 Watts
    Power (max)2500 Watts4200 Watts
    Wire Gauge Size(s)Consult Federal, State,
    and Local codes for branch
    circuit installations
    Consult Federal, State,
    and Local codes for branch
    circuit installations
    Output to
    Motor
    VoltageAdjusts with FrequencyAdjusts with Frequency
    Phase OutSingle-phase (3-wire) OR Three-phaseSingle-phase (3-wire) OR Three-phase
    Frequency Range30-77 Hz (3/4 hp, 0.55 kW) pump
    30-72 Hz (1 hp, 0.75 kW) pump
    30-60 Hz (1.5 hp, 1.1 kW) pump
    30-63 Hz (Single-phase Motors)
    30-78 Hz (1hp, 0.75 kW) pump
    30-72 Hz (1.5 hp, 1.1 kW) pump
    30-60 Hz (2 hp, 1.5 kW) pump
    30-63 Hz (Single-phase Motors)
    Current (max)5.9 A / phase8.1 A / phase
    Wire Gauge Size(s)#6 - #14 * ga.#6 - #14 * ga.
    Pressure SettingFactory Preset50 psi (3.4 bar)50 psi (3.4 bar)
    Adjustment Range25-80 psi (1.7 - 5.5 bar)25-80 psi (1.7 - 5.5 bar)
    Operating
    Conditions(A)
    Temperature
    (at 230 VAC input)
    -13 °F to 122 °F (-25 °C to 50 °C)-13 °F to 122 °F (-25 °C to 50 °C)
    Relative Humidity
    (NEMA 3R)
    20-95%, non-condensing20-95%, non-condensing
    Controller Size(B)
    (approximate)
    Outer Dimensions9-3/4” x 19-3/4” x 5-1/4”
    (25 x 50 x 13 cm)
    9-3/4” x 19-3/4” x 5-1/4”
    (25 x 50 x 13 cm)
    Weight26 lbs (11.8 kg)26 lbs (11.8 kg)
    For Use With(C)Pump (60 Hz)0.5 hp (0.37 kW) pump with
    214505-series motor
    0.75 hp (0.55 kW) pump with
    214507-series motor
    1.0 hp (0.75 kW) pump with
    214508-series motor
    0.75 hp (0.55 kW), 1.0 hp
    (0.75 kW) 1.5 hp (1.1 kW) pump
    with 234514-series motor
    1.0 hp (0.75 kW) pump
    with 214508-series motor
    1.5 hp (1.1 kW) pump
    with 224300-series motor
    2.0 hp (1.5 kW) pump
    with 224301-series motor
    0.75 hp (0.55 kW), 1.0 hp
    (0.75 kW), 1.5 hp (1.1 kW) pump
    with 234514-series motor
    1.0 hp (0.75 kW), 1.5 hp (1.1 kW),
    2.0 hp (1.5 kW) pump
    with 234315-series motor
    FE Motor214505-series
    (0.5 hp, 0.37 kW) single-phase,
    3-wire 214507-series
    (0.75 hp, 0.55 kW)
    single-phase, 3-wire 214508-series
    (1.0 hp, 0.75 kW)
    single-phase, 3-wire 234514-series
    (1.5 hp, 1.1 kW) three-phase
    214508-series (1.0 hp, 0.75 kW)
    single-phase, 3-wire
    224300-series (1.5 hp, 1.1 kW)
    single-phase, 3-wire
    224301-series (2.0 hp, 1.5 kW)
    single-phase, 3-wire
    234514-series (1.5 hp, 1.1 kW)
    three-phase
    234315-series (2.0 hp, 1.5 kW)
    three-phase
    • Notes: Refer to Franklin Electric’s SubDrive/MonoDrive Installation Manual.
    • (A) Operating temperature is specified at full output power when installed as described in Controller Location Selection.
    • (B) Refer to detailed Mounting Dimensions.
    • (C) If a pump other than the default rating is used, refer to Drive Configuration.
    • * Refer to detailed Circuit Breaker and Wire Sizing charts.

    SubDrive30 and SubDrive50

    NEMA 3RSubDrive30SubDrive50
    Indoor/OutdoorModel No.5870205403C5870205503C
    Input from
    Power Source
    Voltage208/230 VAC208/230 /- 10% VAC
    Phase InSingle-phaseSingle-phase
    Frequency60/50 Hz60/50 Hz
    Current (max)23 Amps36 A
    Power Factor~ 0.95~ 0.95
    Power (idle)5 Watts7 Watts
    Power (max)4200 Watts7200 Watts
    Wire Gauge Size(s)Consult Federal, State,
    and Local codes for branch
    circuit installations
    Consult Federal, State, and Local codes for branch circuit installations
    Output to MotorVoltageAdjusts with FrequencyVariable based on frequency
    Phase OutSingle-phase (3-wire) OR Three-phaseSingle-phase (3-wire) OR three-phase
    Frequency Range30-78 Hz (1.5 hp, 1.1 kW) pump30-78 Hz: 1/2-rated mismatched pump with three-phase motor
    30-70 Hz (2 hp, 1.5 kW) pump30-70 Hz: 2/3 or 3/4-rated mismatched pump with three-phase motor
    30-60 Hz (3 hp, 2.2 kW) pump30-60 Hz: Matched pump with three-phase motor
    30-63 Hz (Single-Phase Motors)30-63 Hz: Matched pump with single-phase motor
    Current (max)10.9 A / phase17.8 (three-phase), 17.0 A (single-phase)
    Wire Gauge Size(s)#6 - #14 * ga.#6 - #12* ga.
    Pressure SettingFactory Preset50 psi (3.4 bar)50 psi (3.4 bar)
    Adjustment Range25-80 psi (1.7 - 5.5 bar)Analog Transducer: 5-95 PSI (0.3 - 6.6 bar)
    Pressure Sensor: 25-80 psi (1.7 - 5.5 bar)
    Operating
    Conditions(A)
    Temperature
    (at 230 VAC input)
    -13 °F to 122 °F (-25 °C to 50 °C)-13 °F to 122 °F (-25 °C to 50 °C)
    Relative Humidity20-95%, non-condensing20-95%, non-condensing
    Controller Size(B)
    (approximate)
    Outer Dimensions9-3/4” x 19-3/4” x 5-1/4”
    (25 x 50 x 13 cm)
    26 1/8" x 15 3/8" x 11 1/2" (66 x 39 x 29 cm)
    Weight26 lbs (11.8 kg)31 lbs (14.1 kg)
    For Use With(C)Pump (60 Hz)0.5 hp (0.37 kW) pump with 214505-series motor
    0.75 hp (0.55 kW) pump with 214507-series motor
    1.0 hp (0.75 kW) pump with 214508-Series motor
    1.5 hp (1.1 kW) pump with 224300-Series motor
    2.0 hp (1.5 kW) pump with 224301-Series motor
    0.75 hp (0.55 kW), 1.0 hp (0.75 kW), or 1.5 hp (1.1 kW) pump
    with 234514-Series motor
    1.0 hp (0.75 kW), 1.5 hp (1.1 kW), or 2.0 hp (1.5 kW) pump
    with 234315-Series motor
    1.5 hp (1.1 kW), 2.0 hp (1.5 kW), or 3.0 hp (2.2 kW) pump
    with 234316-Series motor
    0.5 hp (0.37 kW) pump with 214505-Series motor
    0.75 hp (0.55 kW) pump with 214507-Series motor
    1.0 hp (0.75 kW) pump with 214508-Series motor
    1.5 hp (1.1 kW) pump with 224300-Series motor
    2.0 hp (1.5 kW) pump with 224301-Series motor
    3.0 hp (2.2 kW) pump with 224302-Series motor
    0.5 hp (0.37 kW), 0.75 hp (0.55 kW), or 1.0 hp
    (0.75 kW) pump with 234513-Series motor
    0.75 hp (0.55 kW), 1.0 hp (0.75 kW), or 1.5 hp (1.1 kW) pump
    with 234514-Series motor
    1.0 hp (0.75 kW), 1.5 hp (1.1 kW), or 2.0 hp (1.5 kW) pump
    with 234315-Series motor
    1.5 hp (1.1 kW), 2.0 hp (1.5 kW), or 3.0 hp (2.2 kW) pump
    with 234316-Series motor
    3.0 hp (2.2 kW), or 5.0 hp (3.7 kW) pump with 234317-Series motor
    FE Motor214505-Series (0.5 hp, 0.37 kW) single-phase, 3-wire
    214507-Series (0.75 hp, 0.55 kW) single-phase, 3-wire
    214508-Series (1 hp, 0.75 kW) single-phase, 3-wire
    224300-Series (1.5 hp, 1.1 kW) single-phase, 3-wire
    224301-Series (2 hp, 1.5 kW) single-phase, 3-wire
    234513-Series (1.0 hp, 0.75 kW) three-phase
    234514-Series (1.5 hp, 1.1 kW) three-phase
    234315-Series (2.0 hp, 1.5 kW) three-phase
    234316-Series (3.0 hp, 2.2 kW) three-phase
    214505-Series (0.5 hp, 0.37 kW) single-phase, 3-wire
    214507-Series (0.75 hp, 0.55 kW) single-phase, 3-wire
    214508-Series (1.0 hp, 0.75 kW) single-phase, 3-wire
    224300-Series (1.5 hp, 1.1 kW) single-phase, 3-wire
    224301-Series (2.0 hp, 1.5 kW) single-phase, 3-wire
    224302-Series (3.0 hp, 2.2 kW) single-phase, 3-wire
    234513-Series (1.0 hp, 0.75 kW) three-phase
    234514-Series (1.5 hp, 1.1 kW) three-phase
    234315-Series (2.0 hp, 1.5 kW) three-phase
    234316-Series (3.0 hp, 2.2 kW) three-phase
    234317-Series (5.0 hp, 3.7 kW) three-phase
    Surface Pumps2.0–10.9 Amps, three-phase, 230 VAC three-phase2.0 – 17.8 Amps, three-phase, 230 VAC three-phase
    • Notes: Refer to Franklin Electric’s SubDrive/MonoDrive Connect Installation Manual.
    • (A) Operating temperature is specified at full output power when installed as described in Controller Location Selection.
    • (B) Refer to detailed Mounting Dimensions.
    • (C) If a pump other than the default rating is used, refer to Drive Configuration.
    • * Refer to detailed Circuit Breaker and Wire Sizing charts.

    SubDrive100 and SubDrive150

    NEMA 4SubDrive75SubDrive100
    Indoor/OutdoorModel No.58702033845870204104
    Input from
    Power Source
    Voltage190-260 VAC190-260 VAC
    Phase InSingle-phaseSingle-phase
    Frequency60/50 Hz60/50 Hz
    Current (max)19 Amps (RMS)19 Amps (RMS)
    Power Factor1.0 (constant)1.0 (constant)
    Power (idle)65 Watts65 Watts
    Power (max)3800 Watts3800 Watts
    Wire Gauge Size(s)Consult Federal, State, and Local codes for branch circuit installationsConsult Federal, State, and Local
    codes for branch circuit installations
    Output to MotorVoltageAdjusts with FrequencyAdjusts with Frequency
    Phase OutThree-phase (3-wire)Three-phase (3-wire)
    Frequency Range30-80 Hz (1 hp, 0.75 kW) pump30-80 Hz (1 hp, 0.75 kW) pump
    30-70 Hz (1.5 hp, 1.1 kW) pump30-70 Hz (1.5 hp, 1.1 kW) pump
    30-60 Hz (2 hp, 1.5 kW) pump30-60 Hz (2 hp, 1.5 kW) pump
    Current (max)8.1 Amps (RMS, each phase)8.1 Amps (RMS, each phase)
    Wire Gauge Size(s)#6 - #18* ga.#6 - #18 * ga.
    Pressure SettingFactory Preset50 psi (3.4 bar)50 psi (3.4 bar)
    Adjustment Range25-80 psi (1.7 - 5.5 bar)25-80 psi (1.7 - 5.5 bar)
    Operating
    Conditions(A)
    Temperature
    (at 230 VAC input)
    -13 °F to 125 °F (-25 °C to 50 °C)-13 °F to 125 °F (-25 °C to 50 °C)
    Relative Humidity0-100%, condensing0-100%, condensing
    Controller Size(B)
    (approximate)
    Outer Dimensions17-1/2" x 16-3/8" x 11-3/8" (44.45 x 41.59 x 28.89 cm)17-1/2” x 16-3/8” x 11-3/8”
    (44.45 x 41.59 x 28.89 cm)
    28.32 lbs (12.84 kg)
    Weight 28.32 lbs (12.84 kg) 28.32 lbs (12.84 kg)
    For Use With(C)Pump (60 Hz)3/4 hp (0.55 kW) [default]
    1.0 hp (0.75 kw)
    1.5 hp (1.1 kW)
    1 hp (0.75 kW) [default]
    1.5 hp (1.1 kW)
    2 hp (1.5 kW)
    FE Motor234514-Series (1.5 hp, 1.1 kw)234315 - series (2 hp, 1.5 kW)
    • Notes: Refer to Franklin Electric’s SubDrive/MonoDrive Installation Manual.
    • (A) Operating temperature is specified at full output power when installed as described in Controller Location Selection.
    • (B) Refer to detailed Mounting Dimensions.
    • (C) If a pump other than the default rating is used, refer to Drive Configuration.
    • * Refer to detailed Circuit Breaker and Wire Sizing charts.

    SubDrive150 and SubDrive300

    NEMA 4SubDrive150SubDrive300
    Indoor/OutdoorModel No.58702041545870206300
    Input from
    Power
    Source
    Voltage190-260 VAC220-260 VAC
    Phase InSingle-phaseSingle-phase
    Frequency60/50 Hz60/50 Hz
    Current (max)23 Amps (RMS)36 Amps (RMS)
    Power Factor1.0 (constant)1.0 (constant)
    Power (idle)65 Watts65 Watts
    Power (max)4600 Watts7200 Watts
    Wire Gauge
    Size(s)
    Consult Federal, State, and Local
    codes for branch circuit installations
    Consult Federal, State,
    and Localcodes for
    branch circuit installations
    VoltageAdjusts with FrequencyAdjusts with Frequency
    Output
    to Motor
    Phase OutThree-phase (3-wire)Three-phase (3-wire)
    Frequency
    Range
    30-80 Hz (1.5 hp, 1.1 kW) pump30-80 Hz
    (3 hp, 2.2 kW) pump
    30-70 Hz
    (5 hp, 3.7 kW) pump
    30-70 Hz (2 hp, 1.5 kW) pump
    30-60 Hz (3 hp, 2.2 kW) pump
    Current (max)10.9 Amps (RMS, each phase)17.8 Amps (RMS, each phase)
    Pressure
    Setting
    Wire Gauge
    Size(s)
    #6 - #18 * ga.#2 - #18 * ga.
    Factory preset50 psi (3.4 bar)50 psi (3.4 bar)
    Adjustment
    Range
    25-80 psi (1.7 - 5.5 bar)25-80 psi (1.7 - 5.5 bar)
    Operating
    Conditions(A)
    Temperature
    (@ 230 VAC input)
    -13 °F to 125 °F (-25 °C to 50 °C)-13 °F to 125 °F
    (-25 °C to 50 °C)
    Relative
    Humidity
    0-100%, condensing0-100%, condensing
    Controller
    Size(B)
    (approximate)
    Outer
    Dimensions
    17-1/2" x 16-3/8" x 11-3/8"
    (44.45 x 41.59 x 28.89 cm)
    19-7/8” x 17-1/2” x 14-1/4”
    (50.48 x 44.45 x 36.20 cm)
    Weight28.32 lbs (12.84 kg)35.15 lbs (15.94 kg)
    For Use
    With(C)
    Pump (60 Hz)1.5 hp (1.1 kW) [default]
    2 hp (1.5 kW)
    3 hp (2.2 kW)
    3 hp (2.2 kW) [default]
    5 hp (3.7 kW)
    FE Motor234316 - series (3 hp, 2.2 kW)234317-series
    (5 hp, 3.7 kW)
    • Notes: Refer to Franklin Electric’s SubDrive/MonoDrive Installation Manual.
    • (A) Operating temperature is specified at full output power when installed as described in Controller Location Selection.
    • (B) Refer to detailed Mounting Dimensions.
    • (C) If a pump other than the default rating is used, refer to Drive Configuration.
    • * Refer to detailed Circuit Breaker and Wire Sizing charts.

    MonoDrive and MonoDrive XT (NEMA 4)

    NEMA 4MonoDriveMonoDriveXT
    Indoor/OutdoorModel No.58702031145870204114
    Input from
    Power Source
    Voltage190-260 VAC190-260 VAC
    Phase InSingle-phaseSingle-phase
    Frequency60/50 Hz60/50 Hz
    Current (max)5.7 Amps (RMS) 1/2 hp, 0.37 kW system
    8.7 Amps (RMS) 3/4 hp, 0.55 kW system
    11 Amps (RMS) 1 hp, 0.75 kW system
    13 Amps (RMS) 1.5 hp, 1.1 kW system
    16 Amps (RMS) 2 hp, 1.5 kW system
    Power Factor1.0 (constant)1.0 (constant)
    Power (idle)35 Watts65 Watts
    Power (max)1150 Watts (1/2 hp, 0.37 kW) system
    1750 Watts (3/4 hp, 0.55 kW) system
    2150 Watts (1 hp, 0.75 kW) system
    2500 Watts (1.5 hp, 1.1 kW) system
    3100 Watts (2 hp, 1.5 kW) system
    Wire Gauge Size(s)Consult Federal, State, and Local codes
    for branch circuit installations
    Consult Federal, State, and
    Local codes for branch
    circuit installations
    Output to MotorVoltageAdjusts with FrequencyAdjusts with Frequency
    Phase OutSingle-phase (3-wire)Single-phase (3-wire)
    Frequency Range30-60 Hz30-60 Hz
    Current (max)Main Phase: 6 Amps (RMS) 1/2 hp, 0.37 kW system
    Main Phase: 8 Amps (RMS) 3/4 hp, 0.55 kW system
    Main Phase: 10.4 Amps (RMS) 1 hp, 0.75 kW system
    Main Phase: 11.5 Amps (RMS) 1.5 hp, 1.1 kW system
    Main Phase: 13.2 Amps (RMS) 2 hp, 1.5 kW system
    Wire Gauge Size(s)#6 - #18 * ga.#6 - #18 * ga.
    Pressure SettingFactory Preset50 psi (3.4 bar)50 psi (3.4 bar)
    Adjustment Range25-80 psi (1.7 - 5.5 bar)25-80 psi (1.7 - 5.5 bar)
    Operating
    Conditions(A)
    Temperature
    (at 230 VAC input)
    -13 °F to 125 °F (-25 °C to 50 °C)-13 °F to 125 °F (-25 °C to 50 °C)
    Relative Humidity0-100%, condensing0-100%, condensing
    Controller Size(B)
    (approximate)
    Outer Dimensions17-1/2” x 16-3/8” x 11-3/8”
    (44.45 x 41.59 x 28.89 cm)
    17-1/2” x 16-3/8” x 11-3/8”
    (44.45 x 41.59 x 28.89 cm)
    Weight24.14 lbs (10.95 kg)28.32 lbs (12.84 kg)
    For Use With(C)Pump (60 Hz)0.5 hp (0.37 kW) pump with 214505-series motor
    0.75 hp (0.55 kW) pump with 214507-series motor
    1.0 hp (0.75 kW) pump with 214508-series motor
    1.0 hp (0.75 kW) pump with 214508-series motor
    1.5 hp (1.1 kW) pump with 224300-series motor
    2.0 hp (1.5 kW) pump with 224301-series motor
    FE Motor214505-series (0.5 hp, 0.37 kW) single-phase, 3-wire
    214507-series (0.75 hp, 0.55 kW) single-phase, 3-wire (default)
    214508- series (1.0 hp, 0.75 kW) single-phase, 3-wire
    214508-series (1.0 hp, 0.75 kW) single-phase, 3-wire
    224300-series (1.5 hp, 1.1 kW) single-phase, 3-wire (default)
    224301-series (2.0 hp, 1.5 kW) single-phase, 3-wire
    • Notes: Refer to Franklin Electric’s SubDrive/MonoDrive Installation Manual.
    • (A) Operating temperature is specified at full output power when installed as described in Controller Location Selection.
    • (B) Refer to detailed Mounting Dimensions.
    • (C) If a pump other than the default rating is used, refer to Drive Configuration.
    • * Refer to detailed Circuit Breaker and Wire Sizing charts.

    MonoDrive and MonoDrive XT (NEMA 3R)

    NEMA 3RMonoDriveMonoDriveXT
    Indoor/OutdoorModel No.5870205003C5870205203C
    Input from
    Power Source
    Voltage208/230 VAC208/230 VAC
    Phase InSingle-phaseSingle-phase
    Frequency60/50 Hz60/50 Hz
    Current (max)5.7 Amps (RMS) 1/2 hp, 0.37 kW system
    8.7 Amps (RMS) 3/4 hp, 0.55 kW system
    11 Amps (RMS) 1 hp, 0.75 kW system
    13 Amps (RMS) 1.5 hp, 1.1 kW system
    16 Amps (RMS) 2 hp, 1.5 kW system
    Power Factor~ 0.95~ 0.95
    Power (idle)4 Watts5 Watts
    Power (max)2500 Watts4200 Watts
    Wire Gauge Size(s)Consult Federal, State, and Local codes
    for branch circuit installations
    Consult Federal, State, and
    Local codes for branch
    circuit installations
    VoltageAdjusts with FrequencyAdjusts with Frequency
    Output to MotorPhase OutSingle-phase (3-wire)Single-phase (3-wire)
    Frequency Range30-63 Hz30-63 Hz
    Current (max)Main Phase: 6 Amps (RMS) 1/2 hp, 0.37 kW system
    Main Phase: 8 Amps (RMS) 3/4 hp, 0.55 kW system
    Main Phase: 10.4 Amps (RMS) 1 hp, 0.75 kW system
    Main Phase: 11.5 Amps (RMS) 1.5 hp, 1.1 kW system
    Main Phase: 13.2 Amps (RMS) 2 hp, 1.5 kW system
    Wire Gauge Size(s)#6 - #14 * ga.#6 - #14 * ga.
    Pressure SettingFactory Preset50 psi (3.4 bar)50 psi (3.4 bar)
    Adjustment Range25-80 psi (1.7 - 5.5 bar)25-80 psi (1.7 and 5.5 bar)
    Operating
    Conditions(A)
    Temperature
    (at 230 VAC input)
    -13 °F to 122 °F (-25 °C to 50 °C)-13 °F to 122 °F (-25 °C to 50 °C)
    Relative Humidity20-95%, non-condensing20-95%, non-condensing
    Controller Size(B)
    (approximate)
    Outer Dimensions9-3/4” x 16-3/4” x 5-1/4”
    (25 x 42.5 x 13 cm)
    9-3/4” x 19-3/4” x 5-1/4”
    (25 x 50 x 13 cm)
    Weight20 lbs (9 kg)26 lbs (11.8 kg)
    For Use With(C)Pump (60 Hz)0.5 hp (0.37 kW) pump with 214505-series motor
    0.75 hp (0.55 kW) pump with 214507-series motor
    1.0 hp (0.75 kW) pump with 214508-series motor
    1.0 hp (0.75 kW) pump with 214508-series motor
    1.5 hp (1.1 kW) pump with 224300-series motor
    2.0 hp (1.5 kW) pump with 224301-series motor
    FE Motor214505-series (0.5 hp, 0.37 kW) single-phase, 3-wire
    214507-series (0.75 hp, 0.55 kW) single-phase, 3-wire
    214508- series (1.0 hp, 0.75 kW) single-phase, 3-wire
    214508-series (1.0 hp, 0.75 kW) single-phase, 3-wire
    224300-series (1.5 hp, 1.1 kW) single-phase, 3-wire
    224301-series (2.0 hp, 1.5 kW) single-phase, 3-wire
    • Notes: Refer to Franklin Electric’s SubDrive/MonoDrive Installation Manual.
    • (A) Operating temperature is specified at full output power when installed as described in Controller Location Selection.
    • (B) Refer to detailed Mounting Dimensions.
    • (C) If a pump other than the default rating is used, refer to Drive Configuration.
    • * Refer to detailed Circuit Breaker and Wire Sizing charts.

    SubDrive2W

    NEMA 1SubDrive2W
    Indoor/OutdoorModel No.5870203223
    Input from
    Power Source
    Voltage207-260 VAC
    Phase InSingle-phase
    Frequency60/50 Hz
    Current (max)14 Amps (RMS)
    **For circuit breaker sizing
    Power Factor0.7 (approximate)
    Power (idle)20 Watts
    Power (max)1900 Watts
    Wire Gauge Size(s)Consult Federal, State, and Local
    codes for branch circuit installations
    Output to MotorVoltageAdjusts with Frequency
    Phase OutSingle-phase (2-wire)
    Frequency Range30-60 Hz
    Current (max)6 Amps (RMS) 1/2 hp, 0.37 kW system
    8 Amps (RMS) 3/4 hp, 0.55 kW system
    10.4 Amps (RMS) 1 hp, 0.75 kW system
    Wire Gauge Size(s)#6 - #18 * ga.
    Pressure SettingFactory preset50 psi (3.4 bar)
    Adjustment Range25-80 psi (1.7 - 5.5 bar)
    Operating
    Conditions(A)
    Temperature
    (at 230 VAC input)
    -13 °F to 125 °F (-25 °C to 50 °C)
    Relative Humidity10-95%, non-condensing
    Controller Size(B)
    (approximate)
    Outer Dimensions 12-1/4” x 16-1/2” x 9”
    (31.1 x 41.9 x 22.9 cm)
    Weight15.0 lbs (6.80 kg)
    For Use With(C)Pump (60 Hz)1/2 hp pump/motor with 244505-series
    3/4 hp pump/motor with 244507-series [default]
    1 hp pump/motor with 244508-series
    FE MotorNot Available
    • *Product no longer available for sale. For 2-Wire job requirements, see SubDrive Utility.
    • Notes: Refer to Franklin Electric’s SubDrive/MonoDrive Installation Manual.
    • (A) Operating temperature is specified at full output power when installed as described in Controller Location Selection.
    • (B) Refer to detailed Mounting Dimensions.
    • (C) If a pump other than the default rating is used, refer to Drive Configuration.
    • ** Refer to detailed Circuit Breaker and Wire Sizing charts.
  • Kit Information