SubDrive/MonoDrive
SubDrive/MonoDrive
Constant Pressure Variable Frequency Drives (VFD)
Franklin Electric’s constant pressure controllers use state-of-the-art technology to provide constant water pressure through variable speed control of submersible water well pumps.
Applications
- Residential homes
- Restaurants
- Farms
- Schools
- Car washes
- Landscape irrigation systems
-
Benefits
- Constant water pressure with a wide range of settings
- Single-phase input power
- Easy, plug-and-play installation
- Smooth running
- High starting torque
- Soft-start feature prevents water hammer and increases motor life
- Works with small pressure tanks or existing larger tanks
- Advanced filtering to remove radio frequency interference
- Easily replaceable fan kit
- NEMA 3R and NEMA 4 (indoor/outdoor) enclosure options
- UL and cUL listed
- Built-in diagnostics and protection
- Surge Protection
- Short circuit
- Underload
- Overheated controller
- Undervoltage
- Broken pipe detection (SubDrive Connect only)
- Locked pump
- User-configurable underload off time (SubDrive Connect only)
- Open circuit
SubDrive Connect
Franklin Electric’s selection of SubDrive15, SubDrive20, SubDrive30 and SubDrive50 controllers use state-of-the-art technology to provide constant water pressure through variable speed control of submersible water well pumps including connectivity for advanced monitoring, setup and troubleshooting through FE Connect mobile app.
- Single-phase input, 3-wire and three-phase motor control
- 1/2 – 5 hp performance in an array of submersible and above ground pumping systems
- FE Connect Smartphone app for advanced settings, monitoring and troubleshooting
- User-configurable motor frequency range
- NEMA 3R enclosure (indoor/outdoor) that provides a degree of protection against falling rain or sleet
SubDrive (NEMA 4)
SubDrive75, SubDrive100, SubDrive150, and SubDrive300 controllers are designed for three phase motors to provide constant pressure with three-phase performance using single-phase input power. Designed within a NEMA 4 weatherproof enclosure, they offer rugged, watertight variable frequency drive solutions that meets water demand changes.
- Single-phase input, 3-phase motor control
- 1-1/2 – 5 hp performance
- NEMA 4 enclosure (indoor/outdoor) offers robust protection against harsh environmental conditions
MonoDrive and MonoDrive XT (NEMA 4)
MonoDrive and MonoDriveXT are designed to convert a conventional ½ hp to 2 hp pump system to a variable speed constant pressure system by simply replacing the 3-wire control box and pressure switch.
- Single-phase input, 3-wire motor control
- ½ hp to 2 hp performance
- NEMA 4 enclosure (indoor/outdoor) offers robust protection against harsh environmental conditions
Related
Franklin Drive Family Comparison
Submersible Motors Phase Volts Horsepower QD
PumptecPumptec Pumptec
PlusSubDrive
Utility
UT2WSubDrive
Utility
UT3PMonoDrive/
MonoDriveXT
NEMA 4SubDrive
75/100/150/300
NEMA 4SubDrive
15/20/30/50
ConnectSubDrive
Connect Plus1-Phase
2-Wire115 V 1/3 - 1/2 hp x x 230 V 1/3 - 1.5 hp x x x 1-Phase
3-Wire115 V 1/3 - 1/2 hp x x 230 V 1/3 hp x x x 1/2 - 1 hp x x x x x x 1.5 hp x x x x x 2 hp x x x x 3 - 5 hp x 3-Phase 230 V 1/2 hp x 1 - 2 hp x x x 1.5 - 5 hp x x x 5 - 15 hp x 460 V 1/2 - 30 hp x Surface Pumps Phase Volts Horsepower QD
PumptecPumptec Pumptec
PlusSubDrive
Utility
UT2WSubDrive
Utility
UT3PMonoDrive/
MonoDriveXT
NEMA 4SubDrive
75/100/150/300
NEMA 4SubDrive
15/20/30/50
ConnectSubDrive
Connect Plus1-Phase
2-Wire115 V 1/3 - 1 hp x 230 V 1/3 - 2 hp x 3-Phase 230 V 1/2 - 2 hp x x x 3 - 5 hp x x 5 - 15 hp x 460 V 1/2 - 30 hp x Features and Protection Specifications QD
PumptecPumptec Pumptec
PlusSubDrive
Utility
UT2WSubDrive
Utility
UT3PMonoDrive/
MonoDriveXT
NEMA 4SubDrive
75/100/150/300
NEMA 4SubDrive
15/20/30/50
ConnectSubDrive
Connect PlusFeatures Constant Pressure x x x x x x Protection Rating NEMA 3R NEMA 3R NEMA 3R NEMA 3R NEMA 4 NEMA 4 NEMA 3R NEMA 3R Underload x x x x x x x x x Under/Over Voltage x x x x x x x x x Rapid Cycle x x Soft Start Soft Start Soft Start Soft Start Soft Start Overload/
Locked Pumpx x x x x x x x x Open Circuit x x x x x x Short Circuit x x x x x x Phase Imbalance x x x Input/
Output/
ControlPressure Sensor
(Hobbs)x x x x x x Pressure Transducer
(4-20mA)x x x x Run Relay Output Accessory Accessory or
SubDrive300x x Fault Relay Output x x Broken Pipe x x x x Pressure Sensor Error x x x x Auxilliary Control x Run/Stop
Hand/AutoWet Floor Sensor x x x x Lead/Lag/Alternate Accessory,
2 DrivesAccessory,
2 DrivesAccessory,
2 DrivesAccessory,
2 DrivesBuilt-in,
2 DrivesBuilt-in,
up to 8 DrivesMobile App x x -
NEMA 3R Constant Pressure Controllers
VFD Enclosure Type Model No. SubDrive15 Connect NEMA 3R, VARIABLE FREQUENCY 5870205103C SubDrive20 Connect NEMA 3R, VARIABLE FREQUENCY 5870205313C SubDrive30 Connect NEMA 3R, VARIABLE FREQUENCY 5870205403C SubDrive50 Connect NEMA 3R, VARIABLE FREQUENCY 5870205503C - NEMA 3R enclosure (indoor/outdoor) that provides a degree of protection against falling rain or sleet
NEMA 4 Constant Pressure Controllers
VFD Enclosure Type Model No. MonoDrive NEMA 4 VARIABLE FREQUENCY 5870203114 MonoDriveXT NEMA 4 VARIABLE FREQUENCY 5870204114 SubDrive 75 NEMA 4, VARIABLE FREQUENCY 5870203384 SubDrive 100 NEMA 4, VARIABLE FREQUENCY 5870204104 SubDrive 150 NEMA 4, VARIABLE FREQUENCY 5870204154 SubDrive 300 NEMA 4, VARIABLE FREQUENCY 5870206300 - NEMA 4 enclosure (indoor/outdoor) offers robust protection against harsh environmental conditions
-
SubDrive/MonoDrive Accessories
Accessories Detail Used With Part No. Air Screen Kit Helps prevent insects from entering and damaging the internal components of the drive SubDrive15/20/30 Connect and MonoDrive/XT Connect (date code 18A and older) 226550901 SubDrive50 Connect (date code 18A and older) 226550902 Replacement kit for the included standard kit with SubDrive/
MonoDrive Connect models built February 2018 and afterSubDrive15/20/30/50 Connect and MonoDrive/MonoDriveXT Connect (date code 18B and newer) 575214902 Analog Pressure Transducer 4-20mA analog pressure transducer (includes 10 ft cable) All Connect and Utility Models - 100 PSI 226905902 All Connect and Utility Models - 150 PSI 226905903 All Connect and Utility Models - 200 PSI 226905904 Analog PressureTransducer Cable Kit Outdoor rated cable to connect analog pressure transducer to the drive All Connect and Utility models - 10 ft 226910901 All Connect and Utility models - 25 ft 226910902 All Connect and Utility models - 50 ft 226910903 All Connect and Utility models - 100 ft 226910904 All Connect and Utility models - 150 ft 226910905 All Connect and Utility models - 200 ft 226910906 Duplex Alternator Allows a water system to alternate between two parallel pumps controlled by separate drives. All Models 5850012000 Must use pressure sensor; not compatible with analog pressure transducer Duplex Alternator Cable Kit Communication cable kit required to use built-in Duplex
Alternator function in drives equipped with this featureAll Connect models - 10 ft 226895901 All Connect models - 50 ft 226895902 All Connect models - 100 ft 226895903 Enhanced Display Board Replacement Kit Replacement for drives with damaged display, battery holder, or Duplex Alternator communication issue All Connect models 226540912 Enhanced Pressure Input Board Replacement Kit Replacement board for drives that have experienced a surge on the control inputs All Connect models 226540902 Filter (Input) Filter used on the input side of the drive to help eliminate interference All Models 225198901 Filter (Input AMR) Filter used on the input side of the drive to help eliminate
interference with automated meter reading systems.All models (excluding SubDrive30/50,
SubDrive150, and SubDrive300)226030901 Filter (Input IGF) Filter used in the input side of the drive to help eliminate interference on the ground wire All models 226035901 Filter (Output) Filter used on the output side of the drive to help eliminate interference All Models (excluding SubDrive300) 225300901 Filter (Surge Capacitors) 3-lead Capacitor used on the service panel to help eliminate interference All Models 225199901 4-lead Capacitor used on the service panel to help eliminate interference.
Additional ground lead suitable for subpanel installation and effective against LED lighting interference.All Models 225199902 Heatsink Cover Kit Assists in preventing critters from entering and blocking the fan area All NEMA 4 models (excluding SubDrive300) 225805901 Lightning Arrestor Provides additional surge suppression on the single-phase input power side of the drive All Models 150814902 Low Voltage Kit Make adjustments to the input voltage of the SubDrive300 in low voltage applications SubDrive300 225950901 Moisture Sensor Kit External sensor device that shuts down the drive when water is detected All Connect and Connect Plus models 226770901 NEMA 3R Fan Replacement Kit Replacement Fan SubDrive50 Connect 226545903 Replacement fan (date code prior to 08K) SubDrive75 and MonoDrive NEMA 3R 225635907 Replacement fan (date code 14L and after) SubDrive15, MonoDrive Connect and NEMA 3R 226545901 Replacement fan (date code 14L and after) SubDrive20/30, MonoDriveXT Connect and NEMA 3R 226545902 NEMA 4 Cooling Fan Replacement Kit Replacement External fan SubDrive75 and MonoDrive NEMA 4 225635901 SubDrive100/150 and MonoDriveXT NEMA 4 225635902 Replacement External fan (includes 2 fans) SubDrive300 225635903 Replacement Internal Stirring fan All NEMA 4 models 225635904 NEMA 4 Auxiliary Relay Board Offers Run-Indication Relay (date code 09J and after) All NEMA 4 models(excluding SubDrive300) 225755901 NEMA 4 Option Card Offers Run-Indication Relay and Underload Extended
Off-Time Adjustment (date code 09J and after)All NEMA 4 models (excluding SubDrive300) 225880901 Pressure Sensor High Pressure 75-150 PSI - NSF Rated
Adjusts pressure in the watersystem from 75-150 PSI (2-leaded 10 ft cable included)All Models 225970901 Standard Pressure 25-90 PSI - NSF Rated
Adjusts pressure in the watersystem from 25-80 PSI (2-leaded 10 ft cable included)All Models 223995901 Pressure Sensor/High Pressure Shut-Off Kit Includes pressure sensor (25-80 PSI), high pressure shut-off sensor (100 PSI), and 4-leaded 10 ft cable SubDrive300 225495901 Pressure Sensor Input Board Replacement Kit Replacement board for drivesthat have experienced a surge on the pressure sensor input All NEMA 3R models (non-Connect) 226540901 Sensor Cable Kit Indoor, 100 feet of 22 AWG cable (2-leaded) All Models (excluding SubDrive300) 223995902 Indoor, 100 feet of 22 AWG cable (4-leaded) SubDrive300 225495902 Outdoor, 100 feet of 22 AWG cable (2-leaded) All Models (excluding SubDrive300) 226941901 Sensor Direct Burial Cable Designed to run in an underground trench without conduit All Models - 10 ft (3 m) 225800901 All Models - 30 ft (9 m) 225800902 All Models - 100 ft (30 m) 225800903 Tank Drawdown Kit Allows the use of water stored in the during low flow demands SubDrive15/20/30/50 and MonoDrive/MonoDriveXT Connect, and SubDrive300 225770901 SubDrive75/100/150 and MonoDrive/MonoDriveXT NEMA 4 (requires Auxiliary Relay Board or NEMA 4 Option Card kit) 225770901 - N3R = NEMA 3R (Indoor/Outdoor), N4 = NEMA 4 (Outdoor)
SubDrive15 and SubDrive20
NEMA 3R SubDrive15 SubDrive20 Indoor/Outdoor Model No. 5870205103C 5870205313C Input from
Power SourceVoltage 208/230 VAC 208/230 VAC Phase In Single-phase Single-phase Frequency 60/50 Hz 60/50 Hz Current (max) 12 Amps 19 Amps Power Factor ~ 0.95 ~ 0.95 Power (idle) 4 Watts 5 Watts Power (max) 2500 Watts 4200 Watts Wire Gauge Size(s) Consult Federal, State,
and Local codes for branch
circuit installationsConsult Federal, State,
and Local codes for branch
circuit installationsOutput to
MotorVoltage Adjusts with Frequency Adjusts with Frequency Phase Out Single-phase (3-wire) OR Three-phase Single-phase (3-wire) OR Three-phase Frequency Range 30-77 Hz (3/4 hp, 0.55 kW) pump
30-72 Hz (1 hp, 0.75 kW) pump
30-60 Hz (1.5 hp, 1.1 kW) pump
30-63 Hz (Single-phase Motors)30-78 Hz (1hp, 0.75 kW) pump
30-72 Hz (1.5 hp, 1.1 kW) pump
30-60 Hz (2 hp, 1.5 kW) pump
30-63 Hz (Single-phase Motors)Current (max) 5.9 A / phase 8.1 A / phase Wire Gauge Size(s) #6 - #14 * ga. #6 - #14 * ga. Pressure Setting Factory Preset 50 psi (3.4 bar) 50 psi (3.4 bar) Adjustment Range 25-80 psi (1.7 - 5.5 bar) 25-80 psi (1.7 - 5.5 bar) Operating
Conditions(A)Temperature
(at 230 VAC input)-13 °F to 122 °F (-25 °C to 50 °C) -13 °F to 122 °F (-25 °C to 50 °C) Relative Humidity
(NEMA 3R)20-95%, non-condensing 20-95%, non-condensing Controller Size(B)
(approximate)Outer Dimensions 9-3/4” x 19-3/4” x 5-1/4”
(25 x 50 x 13 cm)9-3/4” x 19-3/4” x 5-1/4”
(25 x 50 x 13 cm)Weight 26 lbs (11.8 kg) 26 lbs (11.8 kg) For Use With(C) Pump (60 Hz) 0.5 hp (0.37 kW) pump with
214505-series motor
0.75 hp (0.55 kW) pump with
214507-series motor
1.0 hp (0.75 kW) pump with
214508-series motor
0.75 hp (0.55 kW), 1.0 hp
(0.75 kW) 1.5 hp (1.1 kW) pump
with 234514-series motor1.0 hp (0.75 kW) pump
with 214508-series motor
1.5 hp (1.1 kW) pump
with 224300-series motor
2.0 hp (1.5 kW) pump
with 224301-series motor
0.75 hp (0.55 kW), 1.0 hp
(0.75 kW), 1.5 hp (1.1 kW) pump
with 234514-series motor
1.0 hp (0.75 kW), 1.5 hp (1.1 kW),
2.0 hp (1.5 kW) pump
with 234315-series motorFE Motor 214505-series
(0.5 hp, 0.37 kW) single-phase,
3-wire 214507-series
(0.75 hp, 0.55 kW)
single-phase, 3-wire 214508-series
(1.0 hp, 0.75 kW)
single-phase, 3-wire 234514-series
(1.5 hp, 1.1 kW) three-phase214508-series (1.0 hp, 0.75 kW)
single-phase, 3-wire
224300-series (1.5 hp, 1.1 kW)
single-phase, 3-wire
224301-series (2.0 hp, 1.5 kW)
single-phase, 3-wire
234514-series (1.5 hp, 1.1 kW)
three-phase
234315-series (2.0 hp, 1.5 kW)
three-phase- Notes: Refer to Franklin Electric’s SubDrive/MonoDrive Installation Manual.
- (A) Operating temperature is specified at full output power when installed as described in Controller Location Selection.
- (B) Refer to detailed Mounting Dimensions.
- (C) If a pump other than the default rating is used, refer to Drive Configuration.
- * Refer to detailed Circuit Breaker and Wire Sizing charts.
SubDrive30 and SubDrive50
NEMA 3R SubDrive30 SubDrive50 Indoor/Outdoor Model No. 5870205403C 5870205503C Input from
Power SourceVoltage 208/230 VAC 208/230 /- 10% VAC Phase In Single-phase Single-phase Frequency 60/50 Hz 60/50 Hz Current (max) 23 Amps 36 A Power Factor ~ 0.95 ~ 0.95 Power (idle) 5 Watts 7 Watts Power (max) 4200 Watts 7200 Watts Wire Gauge Size(s) Consult Federal, State,
and Local codes for branch
circuit installationsConsult Federal, State, and Local codes for branch circuit installations Output to Motor Voltage Adjusts with Frequency Variable based on frequency Phase Out Single-phase (3-wire) OR Three-phase Single-phase (3-wire) OR three-phase Frequency Range 30-78 Hz (1.5 hp, 1.1 kW) pump 30-78 Hz: 1/2-rated mismatched pump with three-phase motor 30-70 Hz (2 hp, 1.5 kW) pump 30-70 Hz: 2/3 or 3/4-rated mismatched pump with three-phase motor 30-60 Hz (3 hp, 2.2 kW) pump 30-60 Hz: Matched pump with three-phase motor 30-63 Hz (Single-Phase Motors) 30-63 Hz: Matched pump with single-phase motor Current (max) 10.9 A / phase 17.8 (three-phase), 17.0 A (single-phase) Wire Gauge Size(s) #6 - #14 * ga. #6 - #12* ga. Pressure Setting Factory Preset 50 psi (3.4 bar) 50 psi (3.4 bar) Adjustment Range 25-80 psi (1.7 - 5.5 bar) Analog Transducer: 5-95 PSI (0.3 - 6.6 bar)
Pressure Sensor: 25-80 psi (1.7 - 5.5 bar)Operating
Conditions(A)Temperature
(at 230 VAC input)-13 °F to 122 °F (-25 °C to 50 °C) -13 °F to 122 °F (-25 °C to 50 °C) Relative Humidity 20-95%, non-condensing 20-95%, non-condensing Controller Size(B)
(approximate)Outer Dimensions 9-3/4” x 19-3/4” x 5-1/4”
(25 x 50 x 13 cm)26 1/8" x 15 3/8" x 11 1/2" (66 x 39 x 29 cm) Weight 26 lbs (11.8 kg) 31 lbs (14.1 kg) For Use With(C) Pump (60 Hz) 0.5 hp (0.37 kW) pump with 214505-series motor
0.75 hp (0.55 kW) pump with 214507-series motor
1.0 hp (0.75 kW) pump with 214508-Series motor
1.5 hp (1.1 kW) pump with 224300-Series motor
2.0 hp (1.5 kW) pump with 224301-Series motor
0.75 hp (0.55 kW), 1.0 hp (0.75 kW), or 1.5 hp (1.1 kW) pump
with 234514-Series motor
1.0 hp (0.75 kW), 1.5 hp (1.1 kW), or 2.0 hp (1.5 kW) pump
with 234315-Series motor
1.5 hp (1.1 kW), 2.0 hp (1.5 kW), or 3.0 hp (2.2 kW) pump
with 234316-Series motor0.5 hp (0.37 kW) pump with 214505-Series motor
0.75 hp (0.55 kW) pump with 214507-Series motor
1.0 hp (0.75 kW) pump with 214508-Series motor
1.5 hp (1.1 kW) pump with 224300-Series motor
2.0 hp (1.5 kW) pump with 224301-Series motor
3.0 hp (2.2 kW) pump with 224302-Series motor
0.5 hp (0.37 kW), 0.75 hp (0.55 kW), or 1.0 hp
(0.75 kW) pump with 234513-Series motor
0.75 hp (0.55 kW), 1.0 hp (0.75 kW), or 1.5 hp (1.1 kW) pump
with 234514-Series motor
1.0 hp (0.75 kW), 1.5 hp (1.1 kW), or 2.0 hp (1.5 kW) pump
with 234315-Series motor
1.5 hp (1.1 kW), 2.0 hp (1.5 kW), or 3.0 hp (2.2 kW) pump
with 234316-Series motor
3.0 hp (2.2 kW), or 5.0 hp (3.7 kW) pump with 234317-Series motorFE Motor 214505-Series (0.5 hp, 0.37 kW) single-phase, 3-wire
214507-Series (0.75 hp, 0.55 kW) single-phase, 3-wire
214508-Series (1 hp, 0.75 kW) single-phase, 3-wire
224300-Series (1.5 hp, 1.1 kW) single-phase, 3-wire
224301-Series (2 hp, 1.5 kW) single-phase, 3-wire
234513-Series (1.0 hp, 0.75 kW) three-phase
234514-Series (1.5 hp, 1.1 kW) three-phase
234315-Series (2.0 hp, 1.5 kW) three-phase
234316-Series (3.0 hp, 2.2 kW) three-phase214505-Series (0.5 hp, 0.37 kW) single-phase, 3-wire
214507-Series (0.75 hp, 0.55 kW) single-phase, 3-wire
214508-Series (1.0 hp, 0.75 kW) single-phase, 3-wire
224300-Series (1.5 hp, 1.1 kW) single-phase, 3-wire
224301-Series (2.0 hp, 1.5 kW) single-phase, 3-wire
224302-Series (3.0 hp, 2.2 kW) single-phase, 3-wire
234513-Series (1.0 hp, 0.75 kW) three-phase
234514-Series (1.5 hp, 1.1 kW) three-phase
234315-Series (2.0 hp, 1.5 kW) three-phase
234316-Series (3.0 hp, 2.2 kW) three-phase
234317-Series (5.0 hp, 3.7 kW) three-phaseSurface Pumps 2.0–10.9 Amps, three-phase, 230 VAC three-phase 2.0 – 17.8 Amps, three-phase, 230 VAC three-phase - Notes: Refer to Franklin Electric’s SubDrive/MonoDrive Connect Installation Manual.
- (A) Operating temperature is specified at full output power when installed as described in Controller Location Selection.
- (B) Refer to detailed Mounting Dimensions.
- (C) If a pump other than the default rating is used, refer to Drive Configuration.
- * Refer to detailed Circuit Breaker and Wire Sizing charts.
SubDrive100 and SubDrive150
NEMA 4 SubDrive75 SubDrive100 Indoor/Outdoor Model No. 5870203384 5870204104 Input from
Power SourceVoltage 190-260 VAC 190-260 VAC Phase In Single-phase Single-phase Frequency 60/50 Hz 60/50 Hz Current (max) 19 Amps (RMS) 19 Amps (RMS) Power Factor 1.0 (constant) 1.0 (constant) Power (idle) 65 Watts 65 Watts Power (max) 3800 Watts 3800 Watts Wire Gauge Size(s) Consult Federal, State, and Local codes for branch circuit installations Consult Federal, State, and Local
codes for branch circuit installationsOutput to Motor Voltage Adjusts with Frequency Adjusts with Frequency Phase Out Three-phase (3-wire) Three-phase (3-wire) Frequency Range 30-80 Hz (1 hp, 0.75 kW) pump 30-80 Hz (1 hp, 0.75 kW) pump 30-70 Hz (1.5 hp, 1.1 kW) pump 30-70 Hz (1.5 hp, 1.1 kW) pump 30-60 Hz (2 hp, 1.5 kW) pump 30-60 Hz (2 hp, 1.5 kW) pump Current (max) 8.1 Amps (RMS, each phase) 8.1 Amps (RMS, each phase) Wire Gauge Size(s) #6 - #18* ga. #6 - #18 * ga. Pressure Setting Factory Preset 50 psi (3.4 bar) 50 psi (3.4 bar) Adjustment Range 25-80 psi (1.7 - 5.5 bar) 25-80 psi (1.7 - 5.5 bar) Operating
Conditions(A)Temperature
(at 230 VAC input)-13 °F to 125 °F (-25 °C to 50 °C) -13 °F to 125 °F (-25 °C to 50 °C) Relative Humidity 0-100%, condensing 0-100%, condensing Controller Size(B)
(approximate)Outer Dimensions 17-1/2" x 16-3/8" x 11-3/8" (44.45 x 41.59 x 28.89 cm) 17-1/2” x 16-3/8” x 11-3/8”
(44.45 x 41.59 x 28.89 cm)
28.32 lbs (12.84 kg)Weight 28.32 lbs (12.84 kg) 28.32 lbs (12.84 kg) For Use With(C) Pump (60 Hz) 3/4 hp (0.55 kW) [default]
1.0 hp (0.75 kw)
1.5 hp (1.1 kW)1 hp (0.75 kW) [default]
1.5 hp (1.1 kW)
2 hp (1.5 kW)FE Motor 234514-Series (1.5 hp, 1.1 kw) 234315 - series (2 hp, 1.5 kW) - Notes: Refer to Franklin Electric’s SubDrive/MonoDrive Installation Manual.
- (A) Operating temperature is specified at full output power when installed as described in Controller Location Selection.
- (B) Refer to detailed Mounting Dimensions.
- (C) If a pump other than the default rating is used, refer to Drive Configuration.
- * Refer to detailed Circuit Breaker and Wire Sizing charts.
SubDrive150 and SubDrive300
NEMA 4 SubDrive150 SubDrive300 Indoor/Outdoor Model No. 5870204154 5870206300 Input from
Power
SourceVoltage 190-260 VAC 220-260 VAC Phase In Single-phase Single-phase Frequency 60/50 Hz 60/50 Hz Current (max) 23 Amps (RMS) 36 Amps (RMS) Power Factor 1.0 (constant) 1.0 (constant) Power (idle) 65 Watts 65 Watts Power (max) 4600 Watts 7200 Watts Wire Gauge
Size(s)Consult Federal, State, and Local
codes for branch circuit installationsConsult Federal, State,
and Localcodes for
branch circuit installationsVoltage Adjusts with Frequency Adjusts with Frequency Output
to MotorPhase Out Three-phase (3-wire) Three-phase (3-wire) Frequency
Range30-80 Hz (1.5 hp, 1.1 kW) pump 30-80 Hz
(3 hp, 2.2 kW) pump
30-70 Hz
(5 hp, 3.7 kW) pump30-70 Hz (2 hp, 1.5 kW) pump 30-60 Hz (3 hp, 2.2 kW) pump Current (max) 10.9 Amps (RMS, each phase) 17.8 Amps (RMS, each phase) Pressure
SettingWire Gauge
Size(s)#6 - #18 * ga. #2 - #18 * ga. Factory preset 50 psi (3.4 bar) 50 psi (3.4 bar) Adjustment
Range25-80 psi (1.7 - 5.5 bar) 25-80 psi (1.7 - 5.5 bar) Operating
Conditions(A)Temperature
(@ 230 VAC input)-13 °F to 125 °F (-25 °C to 50 °C) -13 °F to 125 °F
(-25 °C to 50 °C)Relative
Humidity0-100%, condensing 0-100%, condensing Controller
Size(B)
(approximate)Outer
Dimensions17-1/2" x 16-3/8" x 11-3/8"
(44.45 x 41.59 x 28.89 cm)19-7/8” x 17-1/2” x 14-1/4”
(50.48 x 44.45 x 36.20 cm)Weight 28.32 lbs (12.84 kg) 35.15 lbs (15.94 kg) For Use
With(C)Pump (60 Hz) 1.5 hp (1.1 kW) [default]
2 hp (1.5 kW)
3 hp (2.2 kW)3 hp (2.2 kW) [default]
5 hp (3.7 kW)FE Motor 234316 - series (3 hp, 2.2 kW) 234317-series
(5 hp, 3.7 kW)- Notes: Refer to Franklin Electric’s SubDrive/MonoDrive Installation Manual.
- (A) Operating temperature is specified at full output power when installed as described in Controller Location Selection.
- (B) Refer to detailed Mounting Dimensions.
- (C) If a pump other than the default rating is used, refer to Drive Configuration.
- * Refer to detailed Circuit Breaker and Wire Sizing charts.
MonoDrive and MonoDrive XT (NEMA 4)
NEMA 4 MonoDrive MonoDriveXT Indoor/Outdoor Model No. 5870203114 5870204114 Input from
Power SourceVoltage 190-260 VAC 190-260 VAC Phase In Single-phase Single-phase Frequency 60/50 Hz 60/50 Hz Current (max) 5.7 Amps (RMS) 1/2 hp, 0.37 kW system
8.7 Amps (RMS) 3/4 hp, 0.55 kW system
11 Amps (RMS) 1 hp, 0.75 kW system13 Amps (RMS) 1.5 hp, 1.1 kW system
16 Amps (RMS) 2 hp, 1.5 kW systemPower Factor 1.0 (constant) 1.0 (constant) Power (idle) 35 Watts 65 Watts Power (max) 1150 Watts (1/2 hp, 0.37 kW) system
1750 Watts (3/4 hp, 0.55 kW) system
2150 Watts (1 hp, 0.75 kW) system2500 Watts (1.5 hp, 1.1 kW) system
3100 Watts (2 hp, 1.5 kW) systemWire Gauge Size(s) Consult Federal, State, and Local codes
for branch circuit installationsConsult Federal, State, and
Local codes for branch
circuit installationsOutput to Motor Voltage Adjusts with Frequency Adjusts with Frequency Phase Out Single-phase (3-wire) Single-phase (3-wire) Frequency Range 30-60 Hz 30-60 Hz Current (max) Main Phase: 6 Amps (RMS) 1/2 hp, 0.37 kW system
Main Phase: 8 Amps (RMS) 3/4 hp, 0.55 kW system
Main Phase: 10.4 Amps (RMS) 1 hp, 0.75 kW systemMain Phase: 11.5 Amps (RMS) 1.5 hp, 1.1 kW system
Main Phase: 13.2 Amps (RMS) 2 hp, 1.5 kW systemWire Gauge Size(s) #6 - #18 * ga. #6 - #18 * ga. Pressure Setting Factory Preset 50 psi (3.4 bar) 50 psi (3.4 bar) Adjustment Range 25-80 psi (1.7 - 5.5 bar) 25-80 psi (1.7 - 5.5 bar) Operating
Conditions(A)Temperature
(at 230 VAC input)-13 °F to 125 °F (-25 °C to 50 °C) -13 °F to 125 °F (-25 °C to 50 °C) Relative Humidity 0-100%, condensing 0-100%, condensing Controller Size(B)
(approximate)Outer Dimensions 17-1/2” x 16-3/8” x 11-3/8”
(44.45 x 41.59 x 28.89 cm)17-1/2” x 16-3/8” x 11-3/8”
(44.45 x 41.59 x 28.89 cm)Weight 24.14 lbs (10.95 kg) 28.32 lbs (12.84 kg) For Use With(C) Pump (60 Hz) 0.5 hp (0.37 kW) pump with 214505-series motor
0.75 hp (0.55 kW) pump with 214507-series motor
1.0 hp (0.75 kW) pump with 214508-series motor1.0 hp (0.75 kW) pump with 214508-series motor
1.5 hp (1.1 kW) pump with 224300-series motor
2.0 hp (1.5 kW) pump with 224301-series motorFE Motor 214505-series (0.5 hp, 0.37 kW) single-phase, 3-wire
214507-series (0.75 hp, 0.55 kW) single-phase, 3-wire (default)
214508- series (1.0 hp, 0.75 kW) single-phase, 3-wire214508-series (1.0 hp, 0.75 kW) single-phase, 3-wire
224300-series (1.5 hp, 1.1 kW) single-phase, 3-wire (default)
224301-series (2.0 hp, 1.5 kW) single-phase, 3-wire- Notes: Refer to Franklin Electric’s SubDrive/MonoDrive Installation Manual.
- (A) Operating temperature is specified at full output power when installed as described in Controller Location Selection.
- (B) Refer to detailed Mounting Dimensions.
- (C) If a pump other than the default rating is used, refer to Drive Configuration.
- * Refer to detailed Circuit Breaker and Wire Sizing charts.
MonoDrive and MonoDrive XT (NEMA 3R)
NEMA 3R MonoDrive MonoDriveXT Indoor/Outdoor Model No. 5870205003C 5870205203C Input from
Power SourceVoltage 208/230 VAC 208/230 VAC Phase In Single-phase Single-phase Frequency 60/50 Hz 60/50 Hz Current (max) 5.7 Amps (RMS) 1/2 hp, 0.37 kW system
8.7 Amps (RMS) 3/4 hp, 0.55 kW system
11 Amps (RMS) 1 hp, 0.75 kW system13 Amps (RMS) 1.5 hp, 1.1 kW system
16 Amps (RMS) 2 hp, 1.5 kW systemPower Factor ~ 0.95 ~ 0.95 Power (idle) 4 Watts 5 Watts Power (max) 2500 Watts 4200 Watts Wire Gauge Size(s) Consult Federal, State, and Local codes
for branch circuit installationsConsult Federal, State, and
Local codes for branch
circuit installationsVoltage Adjusts with Frequency Adjusts with Frequency Output to Motor Phase Out Single-phase (3-wire) Single-phase (3-wire) Frequency Range 30-63 Hz 30-63 Hz Current (max) Main Phase: 6 Amps (RMS) 1/2 hp, 0.37 kW system
Main Phase: 8 Amps (RMS) 3/4 hp, 0.55 kW system
Main Phase: 10.4 Amps (RMS) 1 hp, 0.75 kW systemMain Phase: 11.5 Amps (RMS) 1.5 hp, 1.1 kW system
Main Phase: 13.2 Amps (RMS) 2 hp, 1.5 kW systemWire Gauge Size(s) #6 - #14 * ga. #6 - #14 * ga. Pressure Setting Factory Preset 50 psi (3.4 bar) 50 psi (3.4 bar) Adjustment Range 25-80 psi (1.7 - 5.5 bar) 25-80 psi (1.7 and 5.5 bar) Operating
Conditions(A)Temperature
(at 230 VAC input)-13 °F to 122 °F (-25 °C to 50 °C) -13 °F to 122 °F (-25 °C to 50 °C) Relative Humidity 20-95%, non-condensing 20-95%, non-condensing Controller Size(B)
(approximate)Outer Dimensions 9-3/4” x 16-3/4” x 5-1/4”
(25 x 42.5 x 13 cm)9-3/4” x 19-3/4” x 5-1/4”
(25 x 50 x 13 cm)Weight 20 lbs (9 kg) 26 lbs (11.8 kg) For Use With(C) Pump (60 Hz) 0.5 hp (0.37 kW) pump with 214505-series motor
0.75 hp (0.55 kW) pump with 214507-series motor
1.0 hp (0.75 kW) pump with 214508-series motor1.0 hp (0.75 kW) pump with 214508-series motor
1.5 hp (1.1 kW) pump with 224300-series motor
2.0 hp (1.5 kW) pump with 224301-series motorFE Motor 214505-series (0.5 hp, 0.37 kW) single-phase, 3-wire
214507-series (0.75 hp, 0.55 kW) single-phase, 3-wire
214508- series (1.0 hp, 0.75 kW) single-phase, 3-wire214508-series (1.0 hp, 0.75 kW) single-phase, 3-wire
224300-series (1.5 hp, 1.1 kW) single-phase, 3-wire
224301-series (2.0 hp, 1.5 kW) single-phase, 3-wire- Notes: Refer to Franklin Electric’s SubDrive/MonoDrive Installation Manual.
- (A) Operating temperature is specified at full output power when installed as described in Controller Location Selection.
- (B) Refer to detailed Mounting Dimensions.
- (C) If a pump other than the default rating is used, refer to Drive Configuration.
- * Refer to detailed Circuit Breaker and Wire Sizing charts.
SubDrive2W
NEMA 1 SubDrive2W Indoor/Outdoor Model No. 5870203223 Input from
Power SourceVoltage 207-260 VAC Phase In Single-phase Frequency 60/50 Hz Current (max) 14 Amps (RMS) **For circuit breaker sizing Power Factor 0.7 (approximate) Power (idle) 20 Watts Power (max) 1900 Watts Wire Gauge Size(s) Consult Federal, State, and Local
codes for branch circuit installationsOutput to Motor Voltage Adjusts with Frequency Phase Out Single-phase (2-wire) Frequency Range 30-60 Hz Current (max) 6 Amps (RMS) 1/2 hp, 0.37 kW system
8 Amps (RMS) 3/4 hp, 0.55 kW system
10.4 Amps (RMS) 1 hp, 0.75 kW systemWire Gauge Size(s) #6 - #18 * ga. Pressure Setting Factory preset 50 psi (3.4 bar) Adjustment Range 25-80 psi (1.7 - 5.5 bar) Operating
Conditions(A)Temperature
(at 230 VAC input)-13 °F to 125 °F (-25 °C to 50 °C) Relative Humidity 10-95%, non-condensing Controller Size(B)
(approximate)Outer Dimensions 12-1/4” x 16-1/2” x 9”
(31.1 x 41.9 x 22.9 cm)Weight 15.0 lbs (6.80 kg) For Use With(C) Pump (60 Hz) 1/2 hp pump/motor with 244505-series
3/4 hp pump/motor with 244507-series [default]
1 hp pump/motor with 244508-seriesFE Motor Not Available - *Product no longer available for sale. For 2-Wire job requirements, see SubDrive Utility.
- Notes: Refer to Franklin Electric’s SubDrive/MonoDrive Installation Manual.
- (A) Operating temperature is specified at full output power when installed as described in Controller Location Selection.
- (B) Refer to detailed Mounting Dimensions.
- (C) If a pump other than the default rating is used, refer to Drive Configuration.
- ** Refer to detailed Circuit Breaker and Wire Sizing charts.
-
Manuals
-
SubDrive/Monodrive Connect Owners Manual (226203103)
-
SubDrive Connect Training Tool (M5070)
-
SubDrive Connect App Instruction Guide (M1775)
-
SubDrive NEMA 3R Owner's Manual (226203101)
-
SubDrive NEMA 1 and NEMA 4 Owner's Manual (M1560)
-
SubDrive NEMA 1 and NEMA 4 Owner's Manual - French (M1560fr)
-
SubDrive NEMA 1 and NEMA 4 Owner's Manual - Portuguese (M1560pt)
-
SubDrive NEMA 1 and NEMA 4 Owner's Manual - Spanish (M1560sp)
Kit Information
-
Air Screen Kit Connect Install Guide for SubDrive50 (226551102)
-
Air Screen Kit Installation Guide for SubDrive NEMA 3R (226551101)
-
Bug Screen Kit for SubDrive Connect (22446910)
-
Duplex Alternator Manual (225589101) (Trilingual)
-
Enhanced Display Board Replacement Install Guide (226541112)
-
Enhanced Sensor Board Replacement Install Guide (226541102)
-
Fan Replacement Install Guide for SubDrive Connect (226546102)
-
Fan Replacement Install Guide for SubDrive50 Connect (226546103)
-
Fan Replacement Kit Installation Guide for NEMA 3R (226546101)
-
Filter (AMR Input) Manual (226030102)
-
Filter (EMI Input) Install Guide (225214101)
-
Filter (EMI Output) Install Guide (225463101)
-
Filter (IGF Input) Manual (226035102)
-
Filter (Surge Capacitor) Install Manual (225216101)
-
Lightning Arrestor Manual (225594101)
-
Moisture Sensor Install Guide (226770101)
-
NEMA 4 Auxiliary Relay Board Install Manual (22573110)
-
NEMA 4 Cooling Fan Replacement Kit Installation Guide (225621101)
-
NEMA 4 Cooling Fan Replacement Installation Guide for SubDrive300 (225657101)
-
NEMA 4 Heatsink Cover Kit Install Guide (225804101)
-
NEMA 4 Internal Stirring Fan Replacement Installation Guide for SubDrive300(225661101)
-
NEMA 4 Option Card Manual (225880901)
-
Pressure Sensor Kit Manual (223991101)
-
Pressure Sensor (High Pressure) Kit Manual (225970101)
-
Pressure Sensor Kit Manual for SubDrive300 (225404101)
-
Pressure Sensor Input Board Replacement Kit Installation Guide for SubDrive NEMA 3R(226541101)
-
Tank Drawdown Kit Installation Guide (225767101)
-