Starters

BAS Building Automation Starter

Starters

BAS Building Automation Starter

Equipped with advanced I/O including Fireman’s Override and damper control, the BAS was designed from the ground up for easy integration with automation systems. With a 200 to 600V input and 1-40A adjustable overload, the BAS is the right starter for almost any job.

Overview


Features & Benefits

  • Designed for ease of integration with automation systems
    • Comprehensive inputs/outputs for building automation systems
    • Reduces installation costs
    • High reliability
  • SmartStart™ patented superior motor protection
    • Electronic overload protection including locked rotor, cycle fault and maximum time to start (due to mis-sized motor or overload)
    • FLA out of calibration indication--ensures installer sets overload correctly based on calculated motor size
  • Advanced control inputs eliminate interposing relays
    • Three dry inputs for auto-run, permissive auto and shutdown
    • Two voltage inputs (12-250VAC) for auto run and fireman’s override
  • Logging retains critical information
    • Logging information is obtainable for starter failure (Factory retrievable only)
    • Last 10 start conditions, including FLA setting, max inrush, run current, time to start, and safety start mode.
    • Last 10 fault conditions, including FLA setting, fault type, fault current, and run time.
  • Universal application
    • Automatically detects voltage (200 to 575VAC)
    • Converts to 24V for control power
    • UL Type 1 and 3R enclosures
  • Lockable enclosure
    • 3R features lockable keypad cover
    • Type 4 & 4X enclosure options available (consult factory)
  • Hand/Off/Auto keypad with LED status indicators
    • Intuitive operation and control with Hand (manual run), Off, and Auto run modes
  • Combination versions include disconnect
    • Motor circuit protection disconnect provides short circuit protection
    • High interrupting ratings for maximum electrical system compatibility
    • No fuses required
    • Lockable handle for safety

Order Information


UL Type 1 - 200-600VAC

Item Maximum Current Branch Protection Included
BAS1-9-P-G1-6-40 1.6 A Yes
BAS1-9-P-G2-5-40 2.5 A Yes
BAS1-9-P-G4-40 4 A Yes
BAS1-9-P-G6-40 6 A Yes
BAS1-9-P-G8-40 8 A Yes
BAS1-9-P-40 9.6 A No
BAS1-18-P-G10-40 10 A Yes
BAS1-18-P-G13-40 13 A Yes
BAS1-18-P-G17-40 17 A Yes
BAS1-32-P-G22-40 22 A Yes
BAS1-18-P-40 22 A No
BAS1-32-P-G26-40 26 A Yes
BAS1-32-P-G32-40 28 A Yes
BAS1-32-P-40 28 A No
BAS1-40-P-G40-40 40 A Yes
BAS1-40-P-40 40 A No

UL Type 3R - 200-600VAC

Item Maximum Current Branch Protection Included
BAS3R-9-P-G1-6-40 1.6 A Yes
BAS3R-9-P-G2-5-40 2.5 A Yes
BAS3R-9-P-G4-40 4 A Yes
BAS3R-9-P-G6-40 6 A Yes
BAS3R-9-P-G8-40 8 A Yes
BAS3R-9-P-40 9.6 A No
BAS3R-18-P-G10-40 10 A Yes
BAS3R-18-P-G13-40 13 A Yes
BAS3R-18-P-G17-40 17 A Yes
BAS3R-32-P-G22-40 22 A Yes
BAS3R-18-P-40 22 A No
BAS3R-32-P-G26-40 26 A Yes
BAS3R-32-P-G32-40 28 A Yes
BAS3R-32-P-40 28 A No
BAS3R-40-P-G40-40 40 A Yes
BAS3R-40-P-40 40 A No