5870202003XD SUBDRIVE UTILITY UT2W INCLUDES TRANSDUCER

Franklin Electric's SubDrive Utility™ Variable Frequency Drives provide an easy-to-install constant pressure solution for 115 V and 230 V single-phase, two-wire systems and 230 V three-wire and three-phase systems up to 2 hp. Requiring only a small pressure tank in most applications, they offer a more compact overall footprint compared to traditional water systems while providing the added value of constant water pressure and built-in motor protection. Designed with a sleek NEMA 3R (Type 3R) enclosure, they are rated for both indoor and outdoor use that provides a degree of protection against falling rain or sleet.

Item: 5870202003XD
Model: SUBDRIVE UTILITY UT2W INCLUDES TRANSDUCER

Ratings

Maximum Motor HP (1 Phase, 2 Wire) 1/2 @ 115 VAC / 1.5 @ 230 VAC
Hz 50/60 Hz
Input Phase Single-Phase
Output Phase Single-Phase 2-Wire
Input Power Factor 0.52
Input Power Max 2500 W
Input voltage single phase (VAC) 115 VAC / 230 VAC
Maximum Output Amps (1 Phase, 2 Wire) 13.1A
Minimum Output Frequency 40Hz (CEN), 30Hz (SUB)
Maximum Output Frequency 60Hz (CEN), 60Hz (SUB)
Maximum Output Current 13.1 A
Output Voltage - 1 Phase, 2 Wire (VAC) 115 VAC / 230 VAC
Pressure Sensor Included No
Pressure Transducer Included YES
Enclosure Rating Type 3R
Minimum Operating Temperature -13 °F
Maximum Operating Temperature 122 °F
Pressure Transducer Included YES
Storage Temperature -13° to 144 °F (-25° to 65 °C)
Maximum Storage Temperature 149 °F
Minimum Storage Temperature -13 °F

Materials of Construction

Shelf Life 1.5 year

Dimensions

Product Weight 19.84 lb
Carton Length 14.13 "
Carton Width 12 "
Carton Height 7.75 "

Other

Drinking Water Agency Approvals ANSI/NSF Standard 61
Electrical Agency Approvals cUL Listed / UL
Warranty Standard Time 12 Mo. from Date of Install / 24 Mo. from Date of Manufacturing