96210535 – 5FR05P4-3W230
The 3200 Series submersible pumps are designed so that all parts of the pump end, including the cable guard, fall within the diameter of Franklin Electric’s industry leading submersible 4-inch motor. This reduced diameter pump end makes it ideal for installations where the well is considered encrusted or tight in comparison to a standard 4-inch well. The 3200 Series also offers a hydraulic stage design optimized for greater water and pressure output when installed at deeper well depths.
Item: | 96210535 |
Model: | 5FR05P4-3W230 |
Ratings |
|
HP | 1/2 hp |
Frequency | 60 Hz |
Phases | Single-Phase |
Amps - Service Factor | 6 A |
Volts | 230 VAC |
Voltage Tolerance (%) | -10.0% / +10.0% |
Wire | 3-Wire |
Motor | Encapsulated |
Continuous Duty | Yes |
Efficiency Service Factor Load [%] | 60.00 % |
Input Phase | Single-Phase |
Lead Retainer Method | Lead Jam Nut |
Maximum Flow Rate - 60 Hz | 7 gpm |
Minimum Flow Rate - 60 Hz | 3 gpm |
Flow | 5 gpm |
Shut Off 60 Hz | 390 ft |
Stages | 13 |
Minimum Cooling Flow | .25 ft/sec |
Motor Ambient Temperature Rating Nominal | 86 °F |
Liquid |
|
Maximum Fluid Temperature | 120 °F |
Materials of Construction |
|
Pump Body Material | AISI 304 Stainless Steel |
Impeller Material | Acetal |
Motor Bracket Material | Thermoplastic |
Check Valve | Yes |
Discharge Material | Thermoplastic |
Intake Screen Material | Thermoplastic |
Thrust Bearing | Kingsbury |
Lead Insulation Material | XLPE |
Diffuser Material | Noryl with 30% Fiberglass |
Cable Guard Material | Thermoplastic |
Dimensions |
|
Discharge | Threaded - FNPT |
Discharge Diameter | 1.25 " |
Product Length | 27.9 " |
Diameter With Cable Guard | 3.75 " |
Motor Length | 9.51 " |
Pump Length | 18.4 " |
Product Weight | 27 lb |
Pump Diameter | 3.9 " |
Other |
|
Component Control Box Part Number | 2801054915 |
Component Motor Part Number | 2145059004GS |
Component Pump Part Number | 96220500 |
Drinking Water Agency Approvals | ANSI/NSF Standard 61 |
Electrical Agency Approvals | UL 778 |
Warranty Standard Time | 12 Mo. from Date of Install / 24 Mo. from Date of Manufacturing |
Applications | Groundwater pumping in clean water well systems ideal for tight well applications 4" and greater |